Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
3102 N TERRELL PL
Apply Date:
11/05/2007
Applicant:
PUEBLO HEATING & COOLING INC *C
Description:
REPLACE: FURNACE (APA)
Contractors:
  • PUEBLO HEATING & COOLING INC *C

Outstanding Activity Conditions

Permit Number - T07ME00747
Permit Status: Expired
Permit Description: REPLACE: FURNACE (APA)
Total Outstanding Activity Conditions - 1
Date Name
11/05/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07ME00747
Permite Description: REPLACE: FURNACE (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
11/09/2007 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
DO NOT USE TAPE TO SEAL A METAL TO METAL CONNECTION AT TOP OF FURNACE SLEEVE.
USE APPROVED DUCT SEALANT
REMOVE ALL OLD ASBESTOS TAPE PRIOR TO APPLYING SEALANT.
INSULATE SHEETMETAL SLEEVE WITH MIN. R4.2 INSULATION
PROVIDE A SEDIMENT TRAP IN GAS LINE AT FURNACE

Documents

File Name Document Type  
None DOCUMENTS VIEW