Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Address:
4313 S BELMAR AV
Address NEW:
4313 S BELMAR AV
Apply Date:
05/30/2007
Applicant:
ENGLISH PHIL
Description:
Air conditioning unit and duct work installation.
Contractors:
  • BREEZE WAYS INC

Outstanding Activity Conditions

Permit Number - T07ME00385
Permit Status: Closed
Permit Description: Air conditioning unit and duct work installation.
Total Outstanding Activity Conditions - 1
Date Name
05/30/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T07ME00385
Permite Description: Air conditioning unit and duct work installation.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/14/2007 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SECURE CONDENSATE DRAIN TO EXTERIOR WALL
TERMINATE WITH AN ELBOW & NIPPLE
2. SECURE THE ELEC. DISCONNECT. PROVIDE THE REQUIRED GFI SERVICE RECEPTACLE ON ROOF WITH A WATERPROOF BUBBLE TYPE COVER
3. SCRATCH OFF THE DATA PLATE NEXT TO THE PROPER HEAT STRIP INSTALLED & FUSE ACCORDINGLY
4. INSULATE ALL EXPOSED DUCT ON ROOF WITH MIN. R8 - 2" DUCT LINER
5. REDWOOD SLEEPERS MUST SPAN ACROSS THE ROOF JOISTS

Documents

File Name Document Type  