Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Apply Date:
04/30/2007
Applicant:
MORANDO MINI
Description:
REPLACEMENT OF TRANE 2.5 TON PAC AC/GAS ( SEXTON 390.1824)
Contractors:
  • AMERICAN HOME MAINTENANCE INC *C

Outstanding Activity Conditions

Permit Number - T07ME00295
Permit Status: Expired
Permit Description: REPLACEMENT OF TRANE 2.5 TON PAC AC/GAS ( SEXTON 390.1824)
Total Outstanding Activity Conditions - 1
Date Name
04/30/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07ME00295
Permite Description: REPLACEMENT OF TRANE 2.5 TON PAC AC/GAS ( SEXTON 390.1824)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
05/09/2007 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE REDUCER WASHERS WHERE ELEC. CONDUIT CONNECTS TO A/C UNIT.
2. CONDENSATE CANNOT TERMINATE INTO A SEWER VENT. NO EXCEPTIONS.
3. PROVIDE A SEDIMENT TRAP ON GAS LINE CONNECTION TO FURNACE.
4. PAINT EXPOSED PVC FITTINGS W/LATEX PAINT

Documents

File Name Document Type  
None DOCUMENTS VIEW