Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
3002 E EASTLAND ST
Apply Date:
02/20/2007
Applicant:
AIRWORKS INC *T
Description:
INSTALL: 3 1/2 TON GAS PACK (APA)
Contractors:
  • AIRWORKS INC *T

Outstanding Activity Conditions

Permit Number - T07ME00085
Permit Status: Expired
Permit Description: INSTALL: 3 1/2 TON GAS PACK (APA)
Total Outstanding Activity Conditions - 1
Date Name
02/20/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07ME00085
Permite Description: INSTALL: 3 1/2 TON GAS PACK (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
03/06/2007 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. BLOCK & CLAMP CONDENSATE DRAIN EVERY 4'
2. PROVIDE 2" R8 DUCT LINER IN EXPOSED SUPPLY DUCT ON ROOF. USE SHEET METAL OVER LEADING EDGES OF INSULATION. SEE 2003 I.E.C.C
3. TERMINATE CONDENSATE TO WITHIN 6" OF THE GROUND OR PROVIDE A DOWNSPOUT ON RAIN GUTTER.

Documents

File Name Document Type  
None DOCUMENTS VIEW