Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
2520 N COYOTE DR #109
Apply Date:
10/19/2007
Applicant:
SLM ARCHITECTS
Description:
TI: OFFICE/WAREHOUSE SUITE 109
Architects:
  • STEPHEN LEON MOOS
Contractors:
  • M B H CONSTRUCTION ,

Permit Reviews

Permit Number - T07CM04115
Permit Status: C of o
Permit Description: TI: OFFICE/WAREHOUSE SUITE 109
Start Date Submittal Complete Date Status  
10/19/2007 COMMERCIAL TI 10/19/2007 COMPLETED Review Details
10/19/2007 3RD PARTY REVIEW-COMMERCIAL TI 11/23/2007 COMPLETED Review Details
11/23/2007 POST 3RD PARTY REVIEW 11/23/2207 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM04115
Permit Status: C of o
Permit Description: TI: OFFICE/WAREHOUSE SUITE 109
Total Outstanding Activity Conditions - 1
Date Name
10/19/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T07CM04115
Permit Description: TI: OFFICE/WAREHOUSE SUITE 109
Total Completed Inspections - 33
Date Description Inspector Results Comments
12/05/2007 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection :*
1. NOT INSTALLED PER PLAN, NO REDLINES ON SITE
2. HOW IS "BOOTLEGGED" ABS WATER CLOSET CONNECTED TO EXISTING N/H CAST IRON?
3. ALL PIPING ON THIS PERMIT TO BE TESTED
4. USE A TAPERED BUSHING AT 3" X 2" REDUCTION
INSERTING A 3" PIECE PAST THE COMBO REQUIRES A FULL SIZE CLEANOUT FOR THAT BRANCH
12/11/2007 PLUMBING - PRE SLAB RMYERS Approved IVRS - Inspection :*
1. SINGLE BATH OK FOR CONCRETE
2. CAST IRON REMOVED AND PLUMBING RE-ROUGHED NOT YET READY FOR INSPECTION
3. SINGLE BATH IS WORK FOR UNIT 109
12/11/2007 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
12/18/2007 ELECTRIC - RECONNECT CCLEMENS Approved IVRS - Inspection :*
1. NEED TO ADD PROPER INSPECTION CODES TO PERMIT SO YOU CAN CALL CORRECT INSPECTIONS
2. ALL WIRING TO BE PER PLAN OR REVISE PLAN AS NEEDED FOR INSPECTIONS
01/09/2008 FRAMING AQUIROZ Approved IVRS - Inspection :*
01/16/2008 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
01/16/2008 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
ALL WINDOWS ARE EXISTING
01/16/2008 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
OK TO SET TILE
01/16/2008 ROOF NAILING JBURGE Approved IVRS - Inspection :*
01/16/2008 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
01/16/2008 NPPO - FINAL ACONNOR Approved N/A
01/16/2008 LANDSCAPE - FINAL ACONNOR Approved N/A
01/16/2008 OUTDOOR LIGHTING FINAL CCLEMENS Approved IVRS - Inspection :*
01/16/2008 ELECTRIC - OUTDOOR LIGHTING CCLEMENS Approved IVRS - Inspection :*
01/16/2008 ELECTRIC - UNDERGROUND CCLEMENS Approved IVRS - Inspection :*
01/16/2008 SIGN - FINAL JYBARRA Approved
01/17/2008 ENGINEERING - FINAL MRUSSO Approved
01/18/2008 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :*
01/29/2008 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
01/30/2008 MECHANICAL - ABOVE CEILING MRAMBER Approved
01/30/2008 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
01/31/2008 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
OK TO TAPE RESTROOM & SEPARATION WALL
02/01/2008 PLUMBING - GAS PRESS TEST FNL RMYERS Approved IVRS - Inspection :*
02/04/2008 BUILDING - PROGRESS AQUIROZ Approved IVRS - Inspection :*
02/08/2008 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
02/11/2008 FIRE SPKLR - FINAL CSCHULTZ Approved
02/11/2008 FIRE - FINAL CSCHULTZ Approved
02/11/2008 FIRE - FINAL CSCHULTZ Approved
02/12/2008 ELECTRIC - INTERMEDIATE CCLEMENS Approved
02/12/2008 ELECTRIC - ABOVE CEILING CCLEMENS Approved
02/12/2008 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :*
02/13/2008 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
02/14/2008 BUILDING - FINAL AQUIROZ Approved

Documents

File Name Document Type  
C OF O_02-14-2008.TIF CERT OF OCC VIEW
T07CM04115_001.TIF CONSTRPLANS VIEW
T07CM04115_002.TIF CONSTRPLANS VIEW
T07CM04115_003.TIF CONSTRPLANS VIEW
T07CM04115_004.TIF CONSTRPLANS VIEW
T07CM04115_005.TIF CONSTRPLANS VIEW
T07CM04115_001.TIF CONSTRPLANS VIEW
T07CM04115_002.TIF CONSTRPLANS VIEW
T07CM04115_003.TIF CONSTRPLANS VIEW
T07CM04115_004.TIF CONSTRPLANS VIEW
T07CM04115_005.TIF CONSTRPLANS VIEW
T07CM04115_006.TIF CONSTRPLANS VIEW
T07CM04115_007.TIF CONSTRPLANS VIEW
T07CM04115_008.TIF CONSTRPLANS VIEW
T07CM04115_009.TIF CONSTRPLANS VIEW
T07CM04115_010.TIF CONSTRPLANS VIEW
T07CM04115_011.TIF CONSTRPLANS VIEW
T07CM04115_012.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW