Permit: T07CM04115
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
2520 N COYOTE DR #109
Address NEW:
2520 N COYOTE DR #109
Apply Date:
10/19/2007
Applicant:
SLM ARCHITECTS
Description:
TI: OFFICE/WAREHOUSE SUITE 109
Architects:
- STEPHEN LEON MOOS
Contractors:
- M B H CONSTRUCTION ,
Permit Reviews
Permit Number - T07CM04115
Permit Status: C of o
Permit Description: TI: OFFICE/WAREHOUSE SUITE 109
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/19/2007 | COMMERCIAL TI | 10/19/2007 | COMPLETED |
| 10/19/2007 | 3RD PARTY REVIEW-COMMERCIAL TI | 11/23/2007 | COMPLETED |
| 11/23/2007 | POST 3RD PARTY REVIEW | 11/23/2207 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM04115
Permit Status: C of o
Permit Description: TI: OFFICE/WAREHOUSE SUITE 109
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/19/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM04115
Permit Description: TI: OFFICE/WAREHOUSE SUITE 109
Total Completed Inspections - 33
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/05/2007 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* 1. NOT INSTALLED PER PLAN, NO REDLINES ON SITE 2. HOW IS "BOOTLEGGED" ABS WATER CLOSET CONNECTED TO EXISTING N/H CAST IRON? 3. ALL PIPING ON THIS PERMIT TO BE TESTED 4. USE A TAPERED BUSHING AT 3" X 2" REDUCTION INSERTING A 3" PIECE PAST THE COMBO REQUIRES A FULL SIZE CLEANOUT FOR THAT BRANCH |
| 12/11/2007 | PLUMBING - PRE SLAB | RMYERS | Approved | IVRS - Inspection :* 1. SINGLE BATH OK FOR CONCRETE 2. CAST IRON REMOVED AND PLUMBING RE-ROUGHED NOT YET READY FOR INSPECTION 3. SINGLE BATH IS WORK FOR UNIT 109 |
| 12/11/2007 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
| 12/18/2007 | ELECTRIC - RECONNECT | CCLEMENS | Approved | IVRS - Inspection :* 1. NEED TO ADD PROPER INSPECTION CODES TO PERMIT SO YOU CAN CALL CORRECT INSPECTIONS 2. ALL WIRING TO BE PER PLAN OR REVISE PLAN AS NEEDED FOR INSPECTIONS |
| 01/09/2008 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 01/16/2008 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 01/16/2008 | U VALUE FOR WINDOW | JBURGE | Approved | IVRS - Inspection :* ALL WINDOWS ARE EXISTING |
| 01/16/2008 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* OK TO SET TILE |
| 01/16/2008 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* |
| 01/16/2008 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* |
| 01/16/2008 | NPPO - FINAL | ACONNOR | Approved | N/A |
| 01/16/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
| 01/16/2008 | OUTDOOR LIGHTING FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 01/16/2008 | ELECTRIC - OUTDOOR LIGHTING | CCLEMENS | Approved | IVRS - Inspection :* |
| 01/16/2008 | ELECTRIC - UNDERGROUND | CCLEMENS | Approved | IVRS - Inspection :* |
| 01/16/2008 | SIGN - FINAL | JYBARRA | Approved | |
| 01/17/2008 | ENGINEERING - FINAL | MRUSSO | Approved | |
| 01/18/2008 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
| 01/29/2008 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 01/30/2008 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | |
| 01/30/2008 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 01/31/2008 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* OK TO TAPE RESTROOM & SEPARATION WALL |
| 02/01/2008 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* |
| 02/04/2008 | BUILDING - PROGRESS | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/08/2008 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
| 02/11/2008 | FIRE SPKLR - FINAL | CSCHULTZ | Approved | |
| 02/11/2008 | FIRE - FINAL | CSCHULTZ | Approved | |
| 02/11/2008 | FIRE - FINAL | CSCHULTZ | Approved | |
| 02/12/2008 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | |
| 02/12/2008 | ELECTRIC - ABOVE CEILING | CCLEMENS | Approved | |
| 02/12/2008 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 02/13/2008 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
| 02/14/2008 | BUILDING - FINAL | AQUIROZ | Approved |