Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
10/04/2007
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI: MEDICAL OFFICE
Architects:
  • EGLIN, EVAN SAR

Permit Reviews

Permit Number - T07CM03965
Permit Status: C of o
Permit Description: TI: MEDICAL OFFICE
Start Date Submittal Complete Date Status  
10/04/2007 PLANS OK TO SUBMIT - 3RD PARTY 10/08/2007 COMPLETED Review Details
10/08/2007 3RD PARTY REVIEW-COMMERCIAL TI 12/03/2007 COMPLETED Review Details
12/03/2007 POST 3RD PARTY REVIEW 12/06/2007 COMPLETED Review Details
12/06/2007 RESUBMITTAL 12/07/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM03965
Permit Status: C of o
Permit Description: TI: MEDICAL OFFICE
Total Outstanding Activity Conditions - 1
Date Name
10/04/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T07CM03965
Permit Description: TI: MEDICAL OFFICE
Total Completed Inspections - 30
Date Description Inspector Results Comments
12/21/2007 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
1) DEMISING WALL-ENSURE PROPER FIRE CAULKING OF ANY PENETRATIONS
2) PLEASE LEAVE A SET OF APPROVED PALNS AND ACTIVITY CARD AT JOB SITE
12/28/2007 PLUMBING - SEWER HCS CONNECT BBENEDON Approved IVRS - Inspection :*
12/28/2007 PLUMBING - PRE SLAB BBENEDON Approved IVRS - Inspection :*
12/28/2007 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
02/06/2008 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
PROVIDE 1" CONDENSATE PIPE AFTER 2 UNITS TEE TOGETHER
SUPPLY & EXHAUST IN RESTROOMS
OK TO SHEETROCK
FINISH DRYER VENT CONNECTION
02/14/2008 FRAMING JBURGE Approved IVRS - Inspection :*
SOFFITS & PONY WALLS COMPLETED
OK TO SHEETROCK
03/13/2008 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
OK TO SET TILES
03/13/2008 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
4" CLOSET FLANGES OK
03/13/2008 PLUMBING - PROGRESS BBENEDON Approved IVRS - Inspection :*
03/13/2008 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
03/18/2008 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
OK FOR CEILING TILES
03/18/2008 TEP CLEARANCE - AM JWEATHER Approved TMPP CLEARED PER R. HOLLANDER
03/20/2008 ENGINEERING - FINAL JBRUCKME Approved APPROVED ON CONDITION, NO OTHER C OF O'S WILL BE GRANTED UNTIL FINAL GRADING INSPECTION APPROVAL.
Tanque Verde Place
T04BU02272
Preliminary Grading Punch list
March 20, 2008

The following item must be completed prior to final approval of the grading permit and Certificate of Occupancy for lots 9, 10, 32-37 AND ALL LOTS OUTSTANDING.

1. Construct all sidewalks as shown on the approved plans.
2. Construct all sidewalk scuppers per approved plans.
3. Construct drainage swale behind lots 44-47 per plan.
4. Clean drainage pipe behind lots 28, 29.
5. Grout rip rap outfalls per approved plan.
6. Install concrete gutters or revise plan.
7. Revise the grading plan per red line drawings.
8. Install stop signs per plan.
9. Expose all storm drain manhole covers.
10. Submit an Engineers certification for lots 1-14.
11. Repair/ replace all broken or damaged sidewalk and ramps that have two or more through cracks per panel.
12. Trim basin and swale slopes to match plan grades and cross section.
13. Show slope grades at southeast side of lot 57. Slopes steeper then 2:1 require grouted rip rap.
14. Covered parking canopies extend 1 foot into the required PAAL. Have Engineer address with Zoning.
15. Provide detail for both type I and II bicycle parking, and provide lighting as noted on approved plan.
16. Show location of all handrails on as-built plan.
17. Provide inlet and outlet flow line elevation for all underground pipe.
18. Provide detail for drainage swale along west edge of property. Sidewalk/porch extends into area for swale.
19. Insure a minimum of 4 ft sidewalk clearance at building pop outs, electrical panels, etc.
20. Insure a minimum 24 ft PAAL at lot 2.
21. Insure water does not pond at all curb ramps.
22. Provide type B post barricades in trash enclosures per approved plan.

Please address above items and call for reinspection.
03/20/2008 RIGHT OF WAY - FINAL PWHIDDON Approved PER EMAIL
03/20/2008 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
03/20/2008 NPPO - FINAL ACONNOR Approved N/A
03/20/2008 LANDSCAPE - FINAL ACONNOR Approved N/A
03/20/2008 FIRE - FINAL LTHOMAS Approved
03/27/2008 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
03/28/2008 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
03/28/2008 ELECTRIC - PROGRESS RHOLLAND Approved IVRS - Inspection :*
03/28/2008 ELECTRIC - TEMP POWER FOR TEST RHOLLAND Approved IVRS - Inspection :*
03/28/2008 ELECTRIC - CONSTRUCTION POWER RHOLLAND Approved IVRS - Inspection :*
03/28/2008 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
03/28/2008 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
03/31/2008 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
APPROVED FOR OCCUPATION
03/31/2008 BUILDING - PROGRESS JBURGE Approved IVRS - Inspection :*
04/01/2008 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
04/01/2008 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection :*
04/01/2008 PERMIT FINALED BFLORES Approved

Documents

File Name Document Type  
C OF O_04-01-2008.TIF CERT OF OCC VIEW
T07CM03965_001.TIF CONSTRPLANS VIEW
T07CM03965_002.TIF CONSTRPLANS VIEW
T07CM03965_003.TIF CONSTRPLANS VIEW
T07CM03965_004.TIF CONSTRPLANS VIEW
T07CM03965_005.TIF CONSTRPLANS VIEW
T07CM03965_006.TIF CONSTRPLANS VIEW
T07CM03965_007.TIF CONSTRPLANS VIEW
T07CM03965_008.TIF CONSTRPLANS VIEW
T07CM03965_009.TIF CONSTRPLANS VIEW
T07CM03965_010.TIF CONSTRPLANS VIEW
T07CM03965_011.TIF CONSTRPLANS VIEW
T07CM03965_012.TIF CONSTRPLANS VIEW
T07CM03965_013.TIF CONSTRPLANS VIEW
T07CM03965_014.TIF CONSTRPLANS VIEW
T07CM03965_015.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW
None DOCUMENTS VIEW