Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address NEW:
10462 E CALLE TRECE
Apply Date:
08/29/2007
Applicant:
REYES ARVAYO
Description:
ADDITION:GREAT ROOM & BATH R1: PROVIDE STEM WALL DETAIL 1/23/08 R2 - Calcs

Outstanding Activity Conditions

Permit Number - T07CM03565
Permit Status: Final
Permit Description: ADDITION:GREAT ROOM & BATH R1: PROVIDE STEM WALL DETAIL 1/23/08 R2 - Calcs
Total Outstanding Activity Conditions - 1
Date Name
08/29/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T07CM03565
Permit Description: ADDITION:GREAT ROOM & BATH R1: PROVIDE STEM WALL DETAIL 1/23/08 R2 - Calcs
Total Completed Inspections - 23
Date Description Inspector Results Comments
01/24/2008 EXCAVATION/LAYOUT REBAR & ZON WNORTH Approved IVRS - Inspection :*
02/04/2008 PLUMBING - ROUGH, SOIL WNORTH Approved IVRS - Inspection :*
1) TO 2' WEST OF ADDITION
2) NOTE: ANY SUPPLY LINES UNDER SLAB MUST BE CONTINOUS OR HAVE SILVER SOLDERED FITTINGS
02/08/2008 PLUMBING - SEWER HCS CONNECT WNORTH Approved IVRS - Inspection :*
1) CONNECTED TO EXISTING YARD 4" TRANSIT LINE
02/15/2008 BUILDING PRE-SLAB WNORTH Approved IVRS - Inspection :*
02/15/2008 STEM WALL/RETAINING WALL WNORTH Approved IVRS - Inspection :*
03/10/2008 REINFORCED MASONRY PRE-GROUT WNORTH Approved IVRS - Inspection :*
03/18/2008 ROOF NAILING WNORTH Approved IVRS - Inspection :*
04/08/2008 MECHANICAL - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
04/08/2008 PLUMBING - GAS PRESSURE TEST WNORTH Approved IVRS - Inspection :*
04/08/2008 PLUMBING - YARD WTR LINE/TEST WNORTH Approved IVRS - Inspection :*
04/11/2008 FRAMING WNORTH Approved IVRS - Inspection :*
05/23/2008 ELECTRIC - UNDERGROUND WNORTH Approved IVRS - Inspection :*
1) NOTE: THE ELECTRIC PANEL ON THE ADDITION IS NOT DESIGNED FOR EXTERIOR USE
2) GREEN BOARD IS NO LONGER PERMITTED FOR USE UNDER TILE OR MARBLE IN A TUB OR SHOWER
06/17/2008 ELECTRIC - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
06/17/2008 SHEET ROCK NAILING WNORTH Approved IVRS - Inspection :*
06/17/2008 U VALUE FOR WINDOW WNORTH Approved IVRS - Inspection :*
09/05/2008 MECHANICAL - FINAL WNORTH Approved IVRS - Inspection :*
09/05/2008 PLUMBING - FINAL WNORTH Approved IVRS - Inspection :*
09/05/2008 PLUMBING - GAS PRESS TEST FNL WNORTH Approved IVRS - Inspection :*
09/05/2008 OUTDOOR LIGHTING FINAL WNORTH Approved IVRS - Inspection :*
09/26/2008 PLUMBING - INTERMEDIATE WNORTH Approved
10/03/2008 PERMIT FINALED JWEATHER Approved
10/03/2008 ELECTRIC - FINAL WNORTH Approved IVRS - Inspection :*
10/03/2008 BUILDING - FINAL WNORTH Approved IVRS - Inspection :*

Documents

File Name Document Type  
T07CM03565_001.TIF CONSTRPLANS VIEW
T07CM03565_002.TIF CONSTRPLANS VIEW
T07CM03565_003.TIF CONSTRPLANS VIEW
T07CM03565_004.TIF CONSTRPLANS VIEW
T07CM03565_005.TIF CONSTRPLANS VIEW
T07CM03565_006.TIF CONSTRPLANS VIEW
T07CM03565_007.TIF CONSTRPLANS VIEW
T07CM03565_008.TIF CONSTRPLANS VIEW
T07CM03565_009.TIF CONSTRPLANS VIEW
T07CM03565_010.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW
None DOCUMENTS VIEW
TRUSSLAYOUT&ENG_016.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW