Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07CM03081
Permit Details
Apply Date:
07/20/2007
Applicant:
HELLER KENT R
Description:
GAS PACK:REPLACE
Permit Reviews
Permit Number - T07CM03081
Permit Status: Final
Permit Description: GAS PACK:REPLACE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/20/2007 | OTHER | 07/20/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM03081
Permit Status: Final
Permit Description: GAS PACK:REPLACE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/20/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07CM03081
Permit Description: GAS PACK:REPLACE
Total Completed Inspections - 7
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/13/2007 | ELECTRIC - FINAL | MRAMBER | Approved | IVRS - Inspection : See detailed listing on site.| 999* - PINK COATED WIRE CANNOT BE USED FOR LINE VOLTAGE GROUND. - PROVIDE APPROVED CONDUIT IN ATTIC SPACE FOR LINE VOLTAGE TO UNIT |
12/13/2007 | PLUMBING - FINAL | MRAMBER | Approved | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE GAS PRESSURE TEST PRIOR TO FINAL |
12/13/2007 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection : See detailed listing on site.| 999* - PROVIDE PROPER FLASHING AT R.T.U (CURB) - PROVIDE CONDENSATE PIPING AT R.T.U - PROVIDE APPROVED DUCT WORK AT UNIT - PROVIDE APPROVED INSULATION AT DUCT WORK - PROVIDE PROPER INSTALLATION METHODS OF FLEXIBLE DUCT WORK WITH APPROVED FASTENERS. - PROVIDE ROOF JACK AT GAS PIPE PENETRATION - PROVIDE ROOF JACK FOR ALL ROOF PENETRATIONS |
05/06/2008 | ELECTRIC - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
05/06/2008 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
05/06/2008 | PLUMBING - GAS PRESS TEST FNL | MRAMBER | Approved | IVRS - Inspection :* |
05/07/2008 | PERMIT FINALED | BFLORES | Approved |