Permit: T07CM02693
Permit Details
Apply Date:
06/22/2007
Applicant:
PEPPER VINER DEVELOPMENT COMPANY *C
Description:
SFR:TD# 16-83-81 T06-M0304 R1 Window exterior trim
Contractors:
- PEPPER VINER DEVELOPMENT COMPANY *C
Permit Reviews
Permit Number - T07CM02693
Permit Status: C of o
Permit Description: SFR:TD# 16-83-81 T06-M0304
R1 Window exterior trim
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/22/2007 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/09/2007 | COMPLETED |
08/10/2007 | REVISION - - 1ST | 08/10/2007 | ACTIVE |
Outstanding Activity Conditions
Permit Number - T07CM02693
Permit Status: C of o
Permit Description: SFR:TD# 16-83-81 T06-M0304
R1 Window exterior trim
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/22/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM02693
Permit Description: SFR:TD# 16-83-81 T06-M0304
R1 Window exterior trim
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/25/2007 | PLUMBING - YARD WTR LINE/TEST | DWALKER | Approved | IVRS - Inspection :* |
07/25/2007 | PLUMBING - ROUGH, SOIL | DWALKER | Approved | IVRS - Inspection :* |
08/21/2007 | ELECTRIC - UFER | WNORTH | Approved | IVRS - Inspection :* REBAR |
08/21/2007 | ELECTRIC - UNDERGROUND | WNORTH | Approved | IVRS - Inspection :* |
08/21/2007 | BUILDING PRE-SLAB | WNORTH | Approved | IVRS - Inspection :* |
08/21/2007 | EXCAVATION/LAYOUT REBAR & ZON | WNORTH | Approved | IVRS - Inspection :* |
10/08/2007 | ROOF NAILING | WNORTH | Approved | IVRS - Inspection :* |
10/08/2007 | EXT METAL CLIPS/EXT SHEATHING | WNORTH | Approved | IVRS - Inspection :* |
10/23/2007 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | IVRS - Inspection :* |
10/23/2007 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection :* |
10/24/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER R. FREIDINGER |
11/07/2007 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
11/07/2007 | PLUMBING - GAS PRESSURE TEST | RFREIDIN | Approved | IVRS - Inspection :* |
11/07/2007 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
12/17/2007 | FRAMING | RFREIDIN | Approved | IVRS - Inspection :* |
12/26/2007 | PLUMBING - SEWER HCS CONNECT | WLAHR | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO SEE CONNECTION |
12/28/2007 | SHEET ROCK NAILING | WLAHR | Approved | IVRS - Inspection :* |
01/14/2008 | PLUMBING - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
01/14/2008 | U VALUE FOR WINDOW | WNORTH | Approved | IVRS - Inspection :* |
01/14/2008 | STUCCO MESH | WNORTH | Approved | IVRS - Inspection :* |
01/26/2008 | ASSURANCE | MCARREON | Approved | |
03/18/2008 | MECHANICAL - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
03/18/2008 | PLUMBING - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
03/18/2008 | ELECTRIC - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
03/18/2008 | BUILDING - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
03/19/2008 | PERMIT FINALED | JWEATHER | Approved |