Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07CM02540
Permit Details
Apply Date:
06/19/2007
Applicant:
CAYLOR CONSTRUCTION COMPANY , RO
Description:
NEW SHELL BLDG FOR OFFICES R1-plumbing revision & roof framing revision.
Architects:
- JOHNS, DAVID F
Contractors:
- CAYLOR CONSTRUCTION COMPANY , RO
Permit Reviews
Permit Number - T07CM02540
Permit Status: Final
Permit Description: NEW SHELL BLDG FOR OFFICES
R1-plumbing revision & roof framing revision.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/19/2007 | PLANS OK TO SUBMIT - COMM | 06/19/2007 | COMPLETED |
| 06/19/2007 | 3RD PARTY REVIEW-COMMERCIAL | 07/25/2007 | COMPLETED |
| 07/25/2007 | POST 3RD PARTY REVIEW | 07/25/2007 | COMPLETED |
| 10/23/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 10/23/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM02540
Permit Status: Final
Permit Description: NEW SHELL BLDG FOR OFFICES
R1-plumbing revision & roof framing revision.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/19/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07CM02540
Permit Description: NEW SHELL BLDG FOR OFFICES
R1-plumbing revision & roof framing revision.
Total Completed Inspections - 29
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/16/2007 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | IVRS - Inspection :* CONTINUOUS FOOTINGS & COLUMN FOOTINGS OK TO POUR |
| 08/16/2007 | ELECTRIC - UFER | CCLEMENS | Approved | IVRS - Inspection :* OK UFER OTHER PIPING SYSTEM BONDING CONNECTIONS WILL BE MADE OVERHEAD OUT OF SERVICE SO THAT THE CONNECTIONS WILL BE ACCESSIBLE -- NEC 250.104 A & B |
| 08/23/2007 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/28/2007 | ELECTRIC - UNDERGROUND | CCLEMENS | Approved | IVRS - Inspection :* OK SERVICE SECONDARY RACEWAYS AND TWO SUB-PANEL RACEWAYS - SINGLE LINE DIAGRAM TO BE REVISED TO SHOW PANELS. |
| 08/29/2007 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS |
| 08/29/2007 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 08/29/2007 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
| 08/29/2007 | PLUMBING - PRE SLAB | RMYERS | Approved | IVRS - Inspection :* |
| 09/04/2007 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/01/2007 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/04/2007 | REINFORCED MASONRY PRE-GROUT | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/08/2007 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/09/2007 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* PENDING REVIEW |
| 11/19/2007 | STUCCO MESH | JBURGE | Approved | IVRS - Inspection :* OK TO STUCCO |
| 11/19/2007 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* |
| 11/19/2007 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* |
| 11/19/2007 | U VALUE FOR WINDOW | JBURGE | Approved | IVRS - Inspection :* |
| 12/24/2007 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 01/23/2008 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 01/23/2008 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
| 01/23/2008 | FIRE - FINAL | LTHOMAS | Approved | |
| 01/23/2008 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 01/23/2008 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 01/23/2008 | SIGN - FINAL | JYBARRA | Approved | |
| 01/23/2008 | NPPO - FINAL | ACONNOR | Approved | |
| 01/23/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 01/24/2008 | ELECTRIC - TEMP POWER FOR TEST | RHOLLAND | Approved | IVRS - Inspection :* |
| 02/04/2008 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
| 02/05/2008 | ENGINEERING - FINAL | MRUSSO | Approved |