Permit: T07CM02412
Permit Details
Apply Date:
06/11/2007
Applicant:
N/A
Description:
ADDITION:2 BEDROOM:1 BATHROOM R-1 RELOCATE ELECTRIC METER FOR 1608 & 1610 E. 8TH Plans submitted for new review of changes 1/8/08 R2 AS-BUILT DRAWINGS W/REVISED PLUMBING 3/13/08
Contractors:
- DESERT VALLEY BUILDERS L L C
Permit Reviews
Permit Number - T07CM02412
Permit Status: Final
Permit Description: ADDITION:2 BEDROOM:1 BATHROOM
R-1 RELOCATE ELECTRIC METER FOR 1608 & 1610 E. 8TH
Plans submitted for new review of changes 1/8/08
R2 AS-BUILT DRAWINGS W/REVISED PLUMBING 3/13/08
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/08/2008 | REVISION - - 2ND | 01/08/2008 | COMPLETED |
01/08/2008 | REVISION - - 2ND | 01/22/2008 | COMPLETED |
02/06/2008 | REVISION - - 2ND | 02/14/2008 | COMPLETED |
02/29/2008 | REVISION - - 2ND | 03/13/2008 | COMPLETED |
03/13/2008 | REVISION - - 3RD | 03/13/2008 | COMPLETED |
06/11/2007 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 06/11/2007 | COMPLETED |
06/12/2007 | RESIDENTIAL BLDG/WWM | 07/10/2007 | COMPLETED |
07/17/2007 | RESUBMITTAL | 07/26/2007 | COMPLETED |
08/03/2007 | RESUBMITTAL | 08/09/2007 | COMPLETED |
11/01/2007 | REVISION - - 1ST | 11/01/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM02412
Permit Status: Final
Permit Description: ADDITION:2 BEDROOM:1 BATHROOM
R-1 RELOCATE ELECTRIC METER FOR 1608 & 1610 E. 8TH
Plans submitted for new review of changes 1/8/08
R2 AS-BUILT DRAWINGS W/REVISED PLUMBING 3/13/08
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/11/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07CM02412
Permit Description: ADDITION:2 BEDROOM:1 BATHROOM
R-1 RELOCATE ELECTRIC METER FOR 1608 & 1610 E. 8TH
Plans submitted for new review of changes 1/8/08
R2 AS-BUILT DRAWINGS W/REVISED PLUMBING 3/13/08
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/10/2007 | PLUMBING - ROUGH, SOIL | DWALKER | Approved | IVRS - Inspection :* |
10/16/2007 | BUILDING PRE-SLAB | EDURAZO | Approved | |
10/16/2007 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | IVRS - Inspection :* |
10/18/2007 | PLUMBING - PRE SLAB | JRIVA | Approved | IVRS - Inspection :* |
11/28/2007 | ELECTRIC - RECONNECT | DWALKER | Approved | IVRS - Inspection :* |
11/28/2007 | ELECTRIC - SERVICE UPGRADE | DWALKER | Approved | IVRS - Inspection :* |
11/28/2007 | ELECTRIC - TEMPORARY SERVICE | DWALKER | Approved | IVRS - Inspection :* |
11/28/2007 | ELECTRIC - CABLE DROP | DWALKER | Approved | IVRS - Inspection :* |
11/28/2007 | ELECTRIC - SERVICE RELOCATION | DWALKER | Approved | IVRS - Inspection :* |
11/29/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR 1608 & 1610 E. 8TH ST. PER D. WALKER |
12/11/2007 | EXT METAL CLIPS/EXT SHEATHING | DWALKER | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) 1608 & 1610 E. 8TH ST HAVE THE SAME NOTES: NAIL ALL EXT. SHEARWALLS TO PLANS/INCLUDING BLOCKING 2) NEED LADDER TO INSPECT ROOF |
12/11/2007 | ROOF NAILING | DWALKER | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/24/2007 | FRAMING | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK A/C BOOTS MINIMUM 2 SIDES 2) NO PLANS ON SITE 3) NO PERMIT ON SITE 4) STUCCO MESH NEEDS TO BE INSTALLED BEFORE INTERMEDIATES ARE PASSED 5) NEED ADDITIONAL RECEPT S.E. CORNER LIVING ROOM UNLESS WINDOW IS BECOMING DOOR 6) NO DWV WATER TEST 7) SUPPLY TEST OK 8) NEED VACUUM BREAKER ON HOSE BIB 9) NEED 1" CLEAR TO WATER HEATER B-VENT AT ROOF SHEATHING 10) NAIL PROTECT DRYER DUCT AT BLOCKING AND TOP PLATE |
12/24/2007 | MECHANICAL - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/24/2007 | PLUMBING - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/24/2007 | ELECTRIC - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/24/2007 | PLUMBING - GAS PRESSURE TEST | WNORTH | Approved | IVRS - Inspection :* |
12/24/2007 | U VALUE FOR WINDOW | WNORTH | Approved | IVRS - Inspection :* |
05/07/2008 | STUCCO MESH | DWALKER | Approved | IVRS - Inspection :* |
05/08/2008 | SHEET ROCK NAILING | DWALKER | Approved | IVRS - Inspection :* |
08/08/2008 | MECHANICAL - FINAL | DWALKER | Approved | IVRS - Inspection :* |
08/08/2008 | PLUMBING - FINAL | DWALKER | Approved | IVRS - Inspection :* |
08/08/2008 | ELECTRIC - FINAL | DWALKER | Approved | IVRS - Inspection :* |
08/08/2008 | BUILDING - FINAL | DWALKER | Approved | IVRS - Inspection :* |
08/12/2008 | PERMIT FINALED | JWEATHER | Approved |