Permit: T07CM02020
Permit Details
Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address:
26 E MAC IVER PL
Address NEW:
26 E MAC IVER PL
Apply Date:
05/15/2007
Applicant:
BOTEO SAUL & BOTEO BAYRON JT/RS
Description:
ADDITON:2 BEDROOMS/BATH & GREAT ROOM
Permit Reviews
Permit Number - T07CM02020
Permit Status: Final
Permit Description: ADDITON:2 BEDROOMS/BATH & GREAT ROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/15/2007 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 05/17/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM02020
Permit Status: Final
Permit Description: ADDITON:2 BEDROOMS/BATH & GREAT ROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/15/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07CM02020
Permit Description: ADDITON:2 BEDROOMS/BATH & GREAT ROOM
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2007 | PLUMBING - ROUGH, SOIL | CRUIZ | Approved | |
| 06/29/2007 | ELECTRIC - UFER | CRUIZ | Approved | INSPECTED UFER-TIED #4 X 20' BAR |
| 06/29/2007 | EXCAVATION/LAYOUT REBAR & ZON | CRUIZ | Approved | IVRS - Inspection :* |
| 07/20/2007 | ROOF NAILING | CRUIZ | Approved | IVRS - Inspection :* |
| 07/24/2007 | EXT METAL CLIPS/EXT SHEATHING | CRUIZ | Approved | IVRS - Inspection :* |
| 08/20/2007 | ELECTRIC - UNDERGROUND | CRUIZ | Approved | IVRS - Inspection :* |
| 08/20/2007 | ELECTRIC - SERVICE UPGRADE | CRUIZ | Approved | IVRS - Inspection :* |
| 08/20/2007 | PLUMBING - SEWER HCS CONNECT | CRUIZ | Approved | IVRS - Inspection :* |
| 08/21/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER C. RUIZ |
| 09/10/2007 | U VALUE FOR WINDOW | CRUIZ | Approved | IVRS - Inspection :* |
| 09/10/2007 | PLUMBING - GAS PRESSURE TEST | CRUIZ | Approved | IVRS - Inspection :* |
| 09/10/2007 | FRAMING | CRUIZ | Approved | IVRS - Inspection :* |
| 09/10/2007 | MECHANICAL - INTERMEDIATE | CRUIZ | Approved | IVRS - Inspection :* |
| 09/10/2007 | PLUMBING - INTERMEDIATE | CRUIZ | Approved | IVRS - Inspection :* |
| 09/10/2007 | ELECTRIC - INTERMEDIATE | CRUIZ | Approved | IVRS - Inspection :* |
| 09/21/2007 | SHEET ROCK NAILING | CRUIZ | Approved | IVRS - Inspection :* |
| 09/21/2007 | STUCCO MESH | CRUIZ | Approved | IVRS - Inspection :* |
| 10/23/2007 | ELECTRIC - FINAL | CRUIZ | Approved | IVRS - Inspection :* |
| 10/31/2007 | MECHANICAL - FINAL | CRUIZ | Approved | |
| 10/31/2007 | PLUMBING - FINAL | CRUIZ | Approved | |
| 10/31/2007 | PLUMBING - GAS PRESS TEST FNL | CRUIZ | Approved | |
| 10/31/2007 | OUTDOOR LIGHTING FINAL | CRUIZ | Approved | IVRS - Inspection :* |
| 10/31/2007 | BUILDING - FINAL | CRUIZ | Approved | IVRS - Inspection :* |