Permit: T07CM01960
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address:
901 W SIMMONS ST
Address NEW:
901 W SIMMONS ST
Apply Date:
05/10/2007
Applicant:
ROSIER CHARLES A
Description:
EXTEND BEDROOM & BATHROOM, ENCLOSE ENTRY, 4 TON GASPAC & REPLACE WH
Permit Reviews
Permit Number - T07CM01960
Permit Status: Expired
Permit Description: EXTEND BEDROOM & BATHROOM, ENCLOSE ENTRY, 4 TON GASPAC & REPLACE WH
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/10/2007 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 05/10/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM01960
Permit Status: Expired
Permit Description: EXTEND BEDROOM & BATHROOM, ENCLOSE ENTRY, 4 TON GASPAC & REPLACE WH
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/10/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07CM01960
Permite Description: EXTEND BEDROOM & BATHROOM, ENCLOSE ENTRY, 4 TON GASPAC & REPLACE WH
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| MECHANICAL - FINAL | N/A | Not Inspected | ||
| 03/10/2008 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* 1) MISSING SMOKIE IN HALLWAY 2) FIRE BLOCKING AT MASTER BEDROOM MISSING 3) PROTECTION PLATES ON ELECTRICAL 4) WIRE NOT GROUNDS AT ONLY 5) GAS PRESSURE TEST OK |
Completed Inspections
Permit Status: Expired
Permit Number: T07CM01960
Permit Description: EXTEND BEDROOM & BATHROOM, ENCLOSE ENTRY, 4 TON GASPAC & REPLACE WH
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/25/2007 | PLUMBING - GAS PRESSURE TEST | CRUIZ | Approved | IVRS - Inspection :* |
| 09/25/2007 | PLUMBING - YARD WTR LINE/TEST | CRUIZ | Approved | IVRS - Inspection :* |
| 10/30/2007 | EXT METAL CLIPS/EXT SHEATHING | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) FASTEN BEDROOM EXTENSION T-141 6" ON CENTER 2) MISSING AB'S BOTTOM PLATE 3) PROVIDE CONTINOUS TIE DOWN 6 X 8 BEAM TO BOTTOM PLATE 4) EXPOSE FOYER OSB 5) MISSING HARDWARE FOYER 6) NO HEADER ENTRY DOOR |
| 10/30/2007 | FRAMING | RCAMACHO | Approved | IVRS - Inspection :* |
| 10/30/2007 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
| 10/30/2007 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
| 10/30/2007 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
| 10/30/2007 | BUILDING PRE-SLAB | RCAMACHO | Approved | IVRS - Inspection :* |
| 10/30/2007 | EXCAVATION/LAYOUT REBAR & ZON | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/10/2008 | U VALUE FOR WINDOW | CRUIZ | Approved | IVRS - Inspection :* |
| 03/19/2008 | ROOF NAILING | CRUIZ | Approved | IVRS - Inspection :* |
| 05/09/2008 | SHEET ROCK NAILING | CRUIZ | Approved | IVRS - Inspection :* |