Permit Details

Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address:
901 W SIMMONS ST
Address NEW:
901 W SIMMONS ST
Apply Date:
05/10/2007
Applicant:
ROSIER CHARLES A
Description:
EXTEND BEDROOM & BATHROOM, ENCLOSE ENTRY, 4 TON GASPAC & REPLACE WH

Permit Reviews

Permit Number - T07CM01960
Permit Status: Expired
Permit Description: EXTEND BEDROOM & BATHROOM, ENCLOSE ENTRY, 4 TON GASPAC & REPLACE WH
Start Date Submittal Complete Date Status  
05/10/2007 RESIDENTIAL BLDG/ZONING-WALKTHRU 05/10/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM01960
Permit Status: Expired
Permit Description: EXTEND BEDROOM & BATHROOM, ENCLOSE ENTRY, 4 TON GASPAC & REPLACE WH
Total Outstanding Activity Conditions - 1
Date Name
05/10/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07CM01960
Permite Description: EXTEND BEDROOM & BATHROOM, ENCLOSE ENTRY, 4 TON GASPAC & REPLACE WH
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
BUILDING - FINAL N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected
03/10/2008 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
1) MISSING SMOKIE IN HALLWAY
2) FIRE BLOCKING AT MASTER BEDROOM MISSING
3) PROTECTION PLATES ON ELECTRICAL
4) WIRE NOT GROUNDS AT ONLY
5) GAS PRESSURE TEST OK

Completed Inspections

Permit Status: Expired
Permit Number: T07CM01960
Permit Description: EXTEND BEDROOM & BATHROOM, ENCLOSE ENTRY, 4 TON GASPAC & REPLACE WH
Total Completed Inspections - 12
Date Description Inspector Results Comments
09/25/2007 PLUMBING - GAS PRESSURE TEST CRUIZ Approved IVRS - Inspection :*
09/25/2007 PLUMBING - YARD WTR LINE/TEST CRUIZ Approved IVRS - Inspection :*
10/30/2007 EXT METAL CLIPS/EXT SHEATHING RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) FASTEN BEDROOM EXTENSION T-141 6" ON CENTER
2) MISSING AB'S BOTTOM PLATE
3) PROVIDE CONTINOUS TIE DOWN 6 X 8 BEAM TO BOTTOM PLATE
4) EXPOSE FOYER OSB
5) MISSING HARDWARE FOYER
6) NO HEADER ENTRY DOOR
10/30/2007 FRAMING RCAMACHO Approved IVRS - Inspection :*
10/30/2007 MECHANICAL - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :*
10/30/2007 PLUMBING - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :*
10/30/2007 ELECTRIC - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :*
10/30/2007 BUILDING PRE-SLAB RCAMACHO Approved IVRS - Inspection :*
10/30/2007 EXCAVATION/LAYOUT REBAR & ZON RCAMACHO Approved IVRS - Inspection :*
03/10/2008 U VALUE FOR WINDOW CRUIZ Approved IVRS - Inspection :*
03/19/2008 ROOF NAILING CRUIZ Approved IVRS - Inspection :*
05/09/2008 SHEET ROCK NAILING CRUIZ Approved IVRS - Inspection :*