Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07CM01861
Permit Details
Apply Date:
05/03/2007
Applicant:
RELIABLE PERMIT MANAGEMENT
Description:
FOUNDATION ONLY FOR CAR WASH
Contractors:
- RIO WEST DEVELOPMENT AND CONSTRU
Permit Reviews
Permit Number - T07CM01861
Permit Status: Final
Permit Description: FOUNDATION ONLY FOR CAR WASH
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/03/2007 | PLANS OK TO SUBMIT - 3RD PARTY | 05/03/2007 | COMPLETED |
05/03/2007 | 3RD PARTY REVIEW-COMMERCIAL | 05/29/2007 | COMPLETED |
05/29/2007 | POST 3RD PARTY REVIEW | 06/08/2007 | COMPLETED |
07/24/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 07/24/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM01861
Permit Status: Final
Permit Description: FOUNDATION ONLY FOR CAR WASH
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/03/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07CM01861
Permit Description: FOUNDATION ONLY FOR CAR WASH
Total Completed Inspections - 14
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/13/2007 | EXCAVATION/LAYOUT REBAR & ZON | AALEGRIA | Approved | IVRS - Inspection :* 1) APPROVED AT SHEET S201 |
06/13/2007 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection :* |
06/29/2007 | STEM WALL/RETAINING WALL | AALEGRIA | Approved | IVRS - Inspection :* |
08/01/2007 | BUILDING PRE-SLAB | AALEGRIA | Approved | IVRS - Inspection :* |
08/01/2007 | PLUMBING - PRE SLAB | RLEDONNE | Approved | IVRS - Inspection :* |
11/08/2007 | ELECTRIC - FINAL | DSANTACR | Approved | |
11/08/2007 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* SEE ALSO T07CM01982 2090 - FINAL APPROVED |
11/08/2007 | PLUMBING - ROUGH, SOIL | RLEDONNE | Approved | IVRS - Inspection :* |
11/09/2007 | REINFORCED MASONRY PRE-GROUT | GDABBS | Approved | IVRS - Inspection :* |
11/09/2007 | ENGINEERING - FINAL | MAVERY | Approved | Hold building and site work under permit T07CM01861. |
11/13/2007 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* |
11/14/2007 | PLUMBING - FINAL | RLEDONNE | Approved | IVRS - Inspection :* |
11/14/2007 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | PER EMAIL TEMP ONLY |
06/18/2008 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved |