Permit: T07CM01807
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
3302 E TERRA ALTA BL
Address NEW:
3302 E TERRA ALTA BL
Apply Date:
05/01/2007
Applicant:
GREG HAVER
Description:
ADDT: DETACHED GARAGE
Permit Reviews
Permit Number - T07CM01807
Permit Status: Expired
Permit Description: ADDT: DETACHED GARAGE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/01/2007 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 05/01/2007 | COMPLETED |
| 07/12/2007 | REVISION - - 1ST | 07/24/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM01807
Permit Status: Expired
Permit Description: ADDT: DETACHED GARAGE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/01/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07CM01807
Permite Description: ADDT: DETACHED GARAGE
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| ELECTRIC - OUTDOOR LIGHTING | N/A | Not Inspected | ||
| OUTDOOR LIGHTING FINAL | N/A | Not Inspected | ||
| 08/20/2007 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GARAGE RECEPTACLES MUST BE GFI BELOW 8' 2) EXPOSED LAMPS ARE NOT PERMITTED IN STORAGE CLOSETS 3) INSTALL FIXTURES WITH COVERS |
| 08/20/2007 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 08/20/2007 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
Completed Inspections
Permit Status: Expired
Permit Number: T07CM01807
Permit Description: ADDT: DETACHED GARAGE
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/10/2007 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | IVRS - Inspection :* |
| 05/17/2007 | STEM WALL/RETAINING WALL | ROHAVER | Approved | IVRS - Inspection :* |
| 05/25/2007 | REINFORCED MASONRY PRE-GROUT | ROHAVER | Approved | IVRS - Inspection :* |
| 06/15/2007 | ROOF NAILING | EDURAZO | Approved | IVRS - Inspection :* |
| 06/22/2007 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
| 06/22/2007 | FRAMING | RCAMACHO | Approved | IVRS - Inspection :* |
| 06/26/2007 | SHEET ROCK NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
| 07/25/2007 | PLUMBING - GAS PRESSURE TEST | WNORTH | Approved | IVRS - Inspection :* |
| 07/25/2007 | ELECTRIC - UNDERGROUND | WNORTH | Approved | IVRS - Inspection :* |
| 08/20/2007 | BUILDING PRE-SLAB | WNORTH | Approved | IVRS - Inspection :* |