Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07CM01661
Permit Details
Apply Date:
04/20/2007
Applicant:
D R HORTON HOMES
Description:
TOWNHOUSE:TD#16-31-23
Contractors:
- D R HORTON HOMES
Permit Reviews
Permit Number - T07CM01661
Permit Status: Si_xpire
Permit Description: TOWNHOUSE:TD#16-31-23
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/20/2007 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 04/24/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM01661
Permit Status: Si_xpire
Permit Description: TOWNHOUSE:TD#16-31-23
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
04/20/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
04/20/2007 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Si_xpire
Permit Number: T07CM01661
Permit Description: TOWNHOUSE:TD#16-31-23
Total Completed Inspections - 27
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/08/2007 | PLUMBING - SEWER HCS CONNECT | RLEDONNE | Approved | IVRS - Inspection :* |
05/08/2007 | PLUMBING - YARD WTR LINE/TEST | RLEDONNE | Approved | IVRS - Inspection :* |
05/08/2007 | PLUMBING - ROUGH, SOIL | RLEDONNE | Approved | IVRS - Inspection :* |
05/14/2007 | BUILDING PRE-SLAB | AALEGRIA | Approved | IVRS - Inspection :* |
05/14/2007 | EXCAVATION/LAYOUT REBAR & ZON | AALEGRIA | Approved | IVRS - Inspection :* |
06/05/2007 | ROOF NAILING | AALEGRIA | Approved | IVRS - Inspection :* |
06/07/2007 | EXT METAL CLIPS/EXT SHEATHING | AALEGRIA | Approved | IVRS - Inspection :* |
06/26/2007 | FRAMING | AALEGRIA | Approved | IVRS - Inspection :* |
06/26/2007 | PLUMBING - GAS PRESSURE TEST | RLEDONNE | Approved | IVRS - Inspection :* |
06/26/2007 | PLUMBING - GAS PRESSURE TEST | RLEDONNE | Approved | IVRS - Inspection :* |
06/26/2007 | PLUMBING - INTERMEDIATE | RLEDONNE | Approved | IVRS - Inspection :* |
06/26/2007 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection :* |
06/27/2007 | STUCCO MESH | AALEGRIA | Approved | IVRS - Inspection :* |
06/28/2007 | MECHANICAL - INTERMEDIATE | AALEGRIA | Approved | IVRS - Inspection :* |
07/05/2007 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
08/09/2007 | ELECTRIC - TEMPORARY SERVICE | DSANTACR | Approved | IVRS - Inspection :* |
08/09/2007 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection :* |
08/10/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEAED PER D. SANTACRUZ |
09/11/2007 | PLUMBING - FINAL | RLEDONNE | Approved | IVRS - Inspection :* |
09/11/2007 | PLUMBING - GAS PRESS TEST FNL | RLEDONNE | Approved | IVRS - Inspection :* |
09/11/2007 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
09/12/2007 | MECHANICAL - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
09/12/2007 | ELECTRIC - UFER | DSANTACR | Approved | |
09/17/2007 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* |
09/18/2007 | ASSURANCE | DROBERTS | Approved | |
09/18/2007 | U VALUE FOR WINDOW | LHANLY | Approved | |
03/14/2008 | PERMIT FINALED | LJACKSON | Approved |