Permit: T07CM01498
Permit Details
Apply Date:
04/11/2007
Applicant:
N/A
Description:
STORAGE BLDG:TD16-83-56
Architects:
- ACORN, KIM BRIAN
Contractors:
- BETTER BUILT BUILDERS INC ,
Permit Reviews
Permit Number - T07CM01498
Permit Status: Final
Permit Description: STORAGE BLDG:TD16-83-56
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/11/2007 | SITE | 04/27/2007 | COMPLETED |
04/11/2007 | COMMERCIAL NEW | 06/27/2007 | COMPLETED |
04/27/2007 | RESUBMITTAL - SITE | 06/27/2007 | COMPLETED |
07/30/2007 | REVISION - - 1ST | 07/31/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM01498
Permit Status: Final
Permit Description: STORAGE BLDG:TD16-83-56
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/11/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07CM01498
Permit Description: STORAGE BLDG:TD16-83-56
Total Completed Inspections - 37
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/02/2007 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1. CONTRACTOR INSTALLED HUB SETS AS REQUIRED BY PCWWM 2. OK TO COVER ROUGH SOIL 3. OK TO COVER SEWER |
08/02/2007 | SITE - SEWER | RMYERS | Approved | IVRS - Inspection :* |
08/02/2007 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
08/14/2007 | PLUMBING - PRE SLAB | RMYERS | Approved | IVRS - Inspection :* OK FOR CONCRETE |
08/14/2007 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
08/14/2007 | ELECTRIC - UFER | CCLEMENS | Approved | IVRS - Inspection :* |
08/24/2007 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection :* |
09/11/2007 | ELECTRIC - UNDERGROUND | CCLEMENS | Approved | IVRS - Inspection :* THIS STRUCTURE TO BE SUPPLIED BY ONLY ONE SERVICE UNLESS IT MEET THE EXCEPTIONS IN NEC 230.2 OR HAS A RATED WALL, MAKING IT AS TWO SEPARATE STRUCTURES. PLANS NOT ON SITE. OK PROVISIONAL COVER OF CATV, PHONE AND SERVICE SECONDARY RACEWAYS - NOTE: A WARNING RIBBON IS TO BE INSTALLED MINIMUM 12" ABOVE SERVICE RACEWAY WHEN YOU BACKFILL |
10/01/2007 | REINFORCED MASONRY PRE-GROUT | AQUIROZ | Approved | IVRS - Inspection :* |
10/10/2007 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* POST YOUR ADDRESS 2" WATER STUB IN AT BLDG. ONLY OK TO COVER - WATER LINE STOPS AT METER LOCATION |
11/13/2007 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection :* |
11/30/2007 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL (P.I.A. must be accepted first) TEMP ONLY |
11/30/2007 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :*SEE T10CM01808 |
11/30/2007 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* NO INSPECTION AT THIS TIME WIRING NOT PER PLAN |
11/30/2007 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* ALL OFFICES AND PARTY WALL WILL BE UNDER TI PERMIT |
11/30/2007 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* ALL OFFICES AND PARTY WALL WILL BE UNDER TI PERMIT |
11/30/2007 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* ALL OFFICES AND PARTY WALL WILL BE UNDER TI PERMIT |
11/30/2007 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* ALL OFFICES AND PARTY WALL WILL BE UNDER TI PERMIT |
11/30/2007 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* ALL OFFICES AND PARTY WALL WILL BE UNDER TI PERMIT |
11/30/2007 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* ALL OFFICES AND PARTY WALL WILL BE UNDER T.I PERMIT |
11/30/2007 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
11/30/2007 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
11/30/2007 | OUTDOOR LIGHTING FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
11/30/2007 | ELECTRIC - OUTDOOR LIGHTING | CCLEMENS | Approved | IVRS - Inspection :* |
11/30/2007 | ELECTRIC - ABOVE CEILING | CCLEMENS | Approved | IVRS - Inspection :* |
11/30/2007 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* |
11/30/2007 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
11/30/2007 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
11/30/2007 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
11/30/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
12/03/2007 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
12/03/2007 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
12/03/2007 | FIRE - FINAL | LTHOMAS | Approved | |
12/05/2007 | NPPO - FINAL | ACONNOR | Approved | |
12/05/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | |
12/06/2007 | ENGINEERING - FINAL | MRUSSO | Approved | |
08/06/2010 | BUILDING - FINAL | LHANLY | Approved | SEE T10CM01808 MODIFICATIONS TO SHELL BUILDING AND SITE |