Permit: T07CM01404
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
8030 S FARMCREEK DR
Address NEW:
8030 S FARMCREEK DR
Apply Date:
04/04/2007
Applicant:
N/A
Description:
GARAGE/STORAGE BLDG: 30 X 40
Contractors:
- SAW ZIT ALL INC
Outstanding Activity Conditions
Permit Number - T07CM01404
Permit Status: Expired
Permit Description: GARAGE/STORAGE BLDG: 30 X 40
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 04/04/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 05/07/2007 | PERMIT 10 CONDITIONS: 1) Permit T07CM01404 includes the construction of and additional structure on the site and installation of a detention basin to assure compliance with the Final Plat restriction of runoff from each lot. 2) The calculated total impervious cover for the lot including driveway and new addition is 17.22% (10.22% over the 7% limit) of the total lot. This equates to a required basin volume of 725 cubic feet. 3) The required basin area is 0.5 feet deep with a width and length of 27 feet each side, or equivalent basin size to accommodate the required volume of 725 cubic feet. 4) The basin shall have a bleed pipe with erosion protection at the downstream side. 5) The basin and any outlet improvement shall be located within the lot, with a 2-ft minimum setback from disturbance area at property line. 6) The basin shall be located at any area down stream side of the lot, provided that the basin is able to receive stormwater runoff from the lot, and be located 10 feet away from any foundations, and setback from the property boundary at least 2 feet. 7) If alternate solution is requested, a water harvesting cistern system which contains equivalent stormwater volume of 725 cubic feet may be inspected for acceptance by DSD Engineering. Otherwise a drainage report prepared by an Arizona registrant shall be required to show alternate solution that meets Final Plat requirements. 8) Minimum 2' setback from property line to disturbance limits shall be maintained. 9) Temporary erosion control devices shall be placed as needed at downstream side of disturbance limits. 10) Call for DSD Engineering pre-construction inspection and intermediate and final inspections at 837-4888. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07CM01404
Permite Description: GARAGE/STORAGE BLDG: 30 X 40
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| GRADING - INTERMEDIATE | N/A | Not Inspected | ||
| GRADING - FINAL | N/A | Not Inspected | ||
| PERMIT FINALED | N/A | Not Inspected | ||
| 05/31/2007 | ENGINEERING PRE-CONSTRUCTION | N/A | Partial Approval | MET WITH HOMEOWNER AND GUY 405-2158 QUESTION WAS RAISED IN REGARD TO BASIN SIZE NEED TO CHECK WITH ELIZABETH REGARDING CONDITIONS OF PERMIT |
Completed Inspections
Permit Status: Expired
Permit Number: T07CM01404
Permit Description: GARAGE/STORAGE BLDG: 30 X 40
Total Completed Inspections - 14
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2007 | BUILDING PRE-SLAB | WNORTH | Approved | IVRS - Inspection :* |
| 06/21/2007 | STEM WALL/RETAINING WALL | WNORTH | Approved | IVRS - Inspection :* |
| 06/21/2007 | EXCAVATION/LAYOUT REBAR & ZON | WNORTH | Approved | IVRS - Inspection :* |
| 11/26/2007 | FRAMING | JRIVA | Approved | IVRS - Inspection :* |
| 11/26/2007 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection :* |
| 11/26/2007 | EXT METAL CLIPS/EXT SHEATHING | JRIVA | Approved | IVRS - Inspection :* |
| 12/07/2007 | BUILDING - PROGRESS | RFREIDIN | Approved | IVRS - Inspection :* |
| 08/01/2008 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | |
| 08/01/2008 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection :* |
| 08/04/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER R. FREIDINGER |
| 08/29/2008 | ELECTRIC - SERVICE UPGRADE | RFREIDIN | Approved | |
| 08/29/2008 | BUILDING - FINAL | RFREIDIN | Approved | |
| 10/16/2008 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 11/03/2008 | ELECTRIC - FINAL | WNORTH | Approved | IVRS - Inspection :* |