Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/02/2007 | PLANS OK TO SUBMIT - 3RD PARTY | 04/02/2007 | COMPLETED |
04/02/2007 | 3RD PARTY REVIEW-COMMERCIAL TI | 04/17/2007 | COMPLETED |
04/17/2007 | POST 3RD PARTY REVIEW | 05/16/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM01361
Permit Status: C of o
Permit Description: TI:OFFICE (1st Tenant)
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/02/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM01361
Permit Description: TI:OFFICE (1st Tenant)
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/29/2007 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* |
05/30/2007 | PLUMBING - PRE SLAB | BBENEDON | Approved | IVRS - Inspection :* |
05/31/2007 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* OK TO POUR |
06/19/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* SUSPENDED ROUGH DUCT OK TO PROCEED SUPPLY & EXHAUST IN RESTROOM OK TO SHEETROCK CONDENSATE DRAINS OK TO INSULATE |
06/19/2007 | FRAMING | JBURGE | Approved | IVRS - Inspection :* OK TO SHEETROCK ONE SIDE |
06/19/2007 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* OK WALLS |
06/29/2007 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* OK TO TAPE THROUGHOUT |
07/02/2007 | FIRE - FINAL | LTHOMAS | Approved | |
08/08/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* OK FOR CEILING TILES |
08/08/2007 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* |
09/17/2007 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* OK TO TILE |
09/19/2007 | SIGN - FINAL | JSONKIN | Approved | |
09/20/2007 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* 10 OK TO SET TILES |
09/20/2007 | NPPO - FINAL | ACONNOR | Approved | |
09/20/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | |
09/20/2007 | RIGHT OF WAY - FINAL | SDAMRON | Approved | PER EMAIL |
10/08/2007 | ENGINEERING - FINAL | JBRUCKME | Approved | 1. C OF O NOT TO BE GIVEN UNTIL THE FINAL GRADING INSPECTION #09190 FOR T04BU00386 IS COMPLETED AND APPROVED. 2. PROVIDE A LETTER FROM THE AZ REGISTERED P.E. THAT CERTIFIES THAT THE PROJECT AND ALL DRAINAGE IS CONSTRUCTED TO THE revised GRADING PLANS. 3. FINAL GRADING INSPECTION WILL BE PERFORMED USING THE C.O.T APPROVED (revised) GRADING PLAN. 4. COMPLETE ALL SITE WORK. 5. PROVIDE ALL BICYCLE PARKING. 6. REMOVE EXCESS CONSTRUCTION ROLLOFFS AND STORAGE YARDS. |
10/15/2007 | ELECTRIC - TEMP POWER FOR TEST | CCLEMENS | Approved | IVRS - Inspection :* |
10/16/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED FOR #131 PER C. CLEMENS |
11/15/2007 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* |
01/14/2008 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* AIR BALANCE OK |
01/22/2008 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
01/25/2008 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* PENDING ELECTRIC FINAL |
01/28/2008 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* |
01/29/2008 | PERMIT FINALED | BFLORES | Approved |