Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07CM01290
Permit Details
Apply Date:
03/30/2007
Applicant:
N/A
Description:
TI: OFFICE
Architects:
- SWAN WAYNE E
Contractors:
- SCOGGIN CONTRACTING INC
Permit Reviews
Permit Number - T07CM01290
Permit Status: C of o
Permit Description: TI: OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/30/2007 | COMMERCIAL TI | 10/11/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM01290
Permit Status: C of o
Permit Description: TI: OFFICE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
03/30/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM01290
Permit Description: TI: OFFICE
Total Completed Inspections - 13
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/31/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
10/31/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
10/31/2007 | FRAMING | GDABBS | Approved | IVRS - Inspection :* EXISTING WORK APPEARS TO BE IN COMPLIANCE W/CODE |
10/31/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
10/31/2007 | NPPO - FINAL | ACONNOR | Approved | N/A |
10/31/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
11/01/2007 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
11/02/2007 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. VERIFY HAVE APPROPRIATE SIZED CIRCUIT FOR 3KW INSTANT HOT 2. PROVIDE DISCONNECTING MEANS FOR INSTANT HOT 3. OK CEILINGS |
11/02/2007 | FIRE - FINAL | LTHOMAS | Approved | |
12/13/2007 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
12/13/2007 | ENGINEERING - FINAL | NKALAHAR | Approved | ELECTRICAL FINAL NOT COMPLETE PLUMBING FINAL NOT COMPLETE BUILDING FINAL NOT COMPLETE PLEASE RECALL AT BLDG FINAL |
02/29/2008 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* |
03/03/2008 | PERMIT FINALED | BFLORES | Approved |