Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Closed
Type:
COMMERCIAL OTHER
Address:
4517 E 29TH ST
Address NEW:
4517 E 29TH ST
Apply Date:
02/08/2007
Applicant:
LARRY COCHRAN
Description:
C OF O FOR MINISKOOL

Outstanding Activity Conditions

Permit Number - T07CM00484
Permit Status: Closed
Permit Description: C OF O FOR MINISKOOL
Total Outstanding Activity Conditions - 1
Date Name
02/08/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Closed
Permit Number: T07CM00484
Permit Description: C OF O FOR MINISKOOL
Total Completed Inspections - 1
Date Description Inspector Results Comments
02/14/2007 BUILDING - PROGRESS LHANLY Approved The results of a preliminary inspection for purposes of a temporary Certificate of Occupancy are as follows:

1) All egress doors have hardware installed that is inaccessible to children. If something were to happen to a teacher in an individual classroom there is no way for the children to safely exit nor notify other adults in a timely manner.
2) The main entrance has an enclosure with a gate that would interfere with a timely exit in the event of an emergency.
3) There is an exhaust vent from a water heater within 10' of a swamp cooler air intake. Vent should be raised 2' above intake.
4) Emergency exit lighting could not be tested. Illuminated exit signs have not been installed.
5) Toilet facilities do not meet code standards for sanitation (caulking of fixtures, split front toilet seats).
6) Kitchen sinks, hand sinks, water closets, lavatories and utility sinks have been improperly installed and or installed without required permits and inspection.
7) Laundry tub has been installed with trap arm lower than horizontal drain.
8) One or more IIB shade structures (canopy over steel frame) have been erected without necessary permits or inspection.
9) One or more VB shade structures (canopy or wood on wood frame) have been erected without necessary permits.
10) Electric service panels are out of date. Refrigerator is using plug adapter for non-grounded system. Plug receptacles are not properly covered in kitchen.
11) Exterior envelope of building has not been maintained at all AC units.


Owner will need to acknowledge that professionally developed floor plans for the site and buildings will need to be presented for code review and inspection before any permanent Certificate of Occupancy may be issued. Further owner will need to acknowledge that items listed above are not the complete list of corrections that will be required for permanent CofO.

Items 4-11 above may be addressed during permanent CofO process. Items 1-3 will have to be addressed before issuing a temporary CofO.

Documents

File Name Document Type  
None CERT OF OCC VIEW
None DOCUMENTS VIEW