Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07BU02517
Permit Details
Apply Date:
12/04/2007
Applicant:
THE WLB GROUP
Description:
GRADING: CUT 5790 FILL 644
Permit Reviews
Permit Number - T07BU02517
Permit Status: Withdrwn
Permit Description: GRADING: CUT 5790 FILL 644
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/18/2008 | RESUBMITTAL - GRADING ALL | 05/20/2008 | COMPLETED |
| 06/25/2008 | RESUBMITTAL - GRADING | 08/11/2008 | ACTIVE |
| 12/04/2007 | PLANS OK TO SUBMIT - GRADING | 12/04/2007 | COMPLETED |
| 12/04/2007 | GRADING | 02/12/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07BU02517
Permit Status: Withdrwn
Permit Description: GRADING: CUT 5790 FILL 644
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 12/04/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 07/01/2008 | NPPO PRE PERMIT INSPECTION MUST BE PERFORMED PRIOR TO GRUBBING OR GRADING. |
| 08/11/2008 | The following 26 conditions apply to permit T07BU02517: 1) Call for Pre-construction meeting, intermediate, special, and final inspections. For a DSD Engineering Inspection, call IVR (740-6970), or contact DSD Engineering at 837-4888, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html 2) For inspection purposes, post the "AZPDES - Posting Requirements" green sheet at construction entrance of the site at beginning of construction activities and maintain this posted document throughout project construction. 3) SWPPP Receiving waters include a tributary to Pima Air Museum Wash. 4) Remaining operator signatures from must be on the site copy of the SWPPP at or before commencement of construction. 5) This Grading Plan and SWPPP are for onsite clearing, utility infrastructure, private paving, drainage improvements including 2 basins, and landscaping associated with Littletown & Wilmot Industrial Park (S06-270) as shown on the approved Grading Plan T07BU02517, associated geotechnical and drainage addenda. 6) A copy of the NOI, Stormwater Pollution Prevention Plan (SWPPP), Grading Plan and Grading Permit shall be kept at the site at all times, until final grading approval. |
| 08/11/2008 | 7) East boundary contains an underground fiber optic cable; all work within this easement must be coordinated with the proper utilities prior to any site construction. 8) Temporary erosion/stormwater controls may be field adjusted with discussions with operators and engineer of record as necessary along disturbance limits for this project. 9) Temporary material or vehicle staging / stockpile area, and designated concrete washout locations shall not be located in or near the floodplain, basin, or water harvesting areas. 10) Dust control methods such as water truck will be provided, as well as daily sweeping of public streets. 11) Permit for private sewer, manholes and lift station is required. 12) Contact Permits and Codes (791-5100) for any questions regarding any right-of-way permit or PIA requirements for improvements within the public right-of-way. |
| 08/11/2008 | 13) Special inspections may be required for the sewer, signage, and basins. 14) Install street name signs with R1-1 at roadway entering from Wilmot Road. Install W14-2a (No Outlet) plaque beneath street name signs at roadway entering from Wilmot Rd. 15) Call for special inspection for traffic signage. 16) Contact City of Tucson DSD Engineering Inspectors at 837-4888 for private street inspections. 17) The number and location of trees within existing and future sight visibility triangles may be restricted or modified by the City of Tucson in order to preserve visibility. 18) Separate building permit applications are required for any walls. 19) Any revision to the Grading Plan may require a re-submittal of a revised grading plan for review. Contact DSD Engineering to discuss changes in grading design. 20) If grading construction is expected to last longer than the expiration date of the grading permit, contact DSD to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required. |
| 08/11/2008 | 21) Prior to final approval, as-builts will be required. Submit copies of pavement soils reports including geotechnical engineering field observations/testing. Letters of completion are required for basins and project (private street) completion. 22) There shall be no disturbance outside of the approved disturbance/grading limits. Stop Work Order may be issued for disturbance of wash areas. 23) No grading shall begin until all required SWPPP controls are installed. 24) Prior to request for final inspection approval, any outstanding fees shall be paid. 25) The permitee shall notify DSD when the grading operation is ready for final grading inspection. Final grading approval shall not be given until all work, including installation of all drainage improvements, utility trenches are backfilled, private paving and curb, permanent protective devices, all erosion control measures have been completed, and all conditions of permit are completed. 26) Prior to request for final grading inspection approval, all permanent erosion control improvements shall be installed and accepted by DSD including rock / established revegetation for all disturbed areas if not improved as per approved plan. |
Outstanding Inspections
Permit Status: Withdrwn
Permit Number: T07BU02517
Permite Description: GRADING: CUT 5790 FILL 644
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| NPPO PRE PERMIT INSPECTION | N/A | Not Inspected | ||
| STORMWATER FOLLOW-UP INSP | N/A | Not Inspected | ||
| LANDSCAPE INSPECTION | N/A | Not Inspected | ||
| GRADING - CHECK FOR ACTIVITY | N/A | Not Inspected | ||
| GRADING - INTERMEDIATE | N/A | Not Inspected | ||
| GRADING - FINAL | N/A | Not Inspected |