Permit: T06PL02155
Permit Details
Apply Date:
11/22/2006
Applicant:
LONE PLUMBING INC *C
Description:
REPLACE GAS LINE (APA)
Contractors:
- LONE PLUMBING INC *C
Outstanding Activity Conditions
Permit Number - T06PL02155
Permit Status: Expired
Permit Description: REPLACE GAS LINE (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/22/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06PL02155
Permite Description: REPLACE GAS LINE (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/24/2006 | PLUMBING - GAS PRESSURE TEST | N/A | Partial Approval | IVRS - Inspection :* 1. GAS PIPE REPAIR & PRESSURE TEST IS OK 2. GAS UTILITY CLEARANCE GIVEN 3. WATER HEATER SAFETY DEVICES SHALL BE CORRECTED 4. T & P DRAIN SHALL GRAVITY DRAIN TO EXTERIOR AND SHALL BE OPERATIONAL. 5. SECURE VENT CONNECTOR W/SCREWS 6. RAISE B VENT TO ABOVE COOLER 7. PROVIDE ELECTRICAL BONDING. |