Permit: T06PL01535
Permit Details
Apply Date:
08/24/2006
Applicant:
DELGADO SAMUEL
Description:
REPLACE:GAS LINE R1 - Repl water heater
Outstanding Activity Conditions
Permit Number - T06PL01535
Permit Status: Expired
Permit Description: REPLACE:GAS LINE R1 - Repl water heater
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/24/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06PL01535
Permite Description: REPLACE:GAS LINE R1 - Repl water heater
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/12/2006 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* ADD REPLACE WH TO PERMIT. COMPLETE WH VENT - TYPE B REQUIRED COMPLETE T&P TERMINATION. INSTALL SEDIMENT TRAP AT WH. AGA VALVE & FLEX REQUIRED. BONDING OF GAS PIPING AND WATER PIPING. PLEASE INSTALL HB VAC BREAKERS ON NEW WATER REPIPE. |
Completed Inspections
Permit Status: Expired
Permit Number: T06PL01535
Permit Description: REPLACE:GAS LINE R1 - Repl water heater
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/12/2006 | PLUMBING - GAS PRESSURE TEST | BBENEDON | Approved | IVRS - Inspection :* |