Permit: T06PL00912
Permit Details
Status:
Expired
Type:
MULTI FAMILY OTHER
Address:
6939 E GOLF LINKS CI
Address NEW:
6939 E GOLF LINKS CI
Apply Date:
06/02/2006
Applicant:
PATRICIA SABALA
Description:
GAS: RECONNECT
Permit Reviews
Permit Number - T06PL00912
Permit Status: Expired
Permit Description: GAS: RECONNECT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/02/2006 | PLUMBING | 06/02/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06PL00912
Permit Status: Expired
Permit Description: GAS: RECONNECT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/02/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06PL00912
Permite Description: GAS: RECONNECT
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| PLUMBING - FINAL | N/A | Not Inspected | ||
| 06/09/2006 | PLUMBING - GAS RECONNECT | N/A | Partial Approval | IVRS - Inspection :* 20 PSI TEST EXISTING PIPING OK 1. PROVIDE RIDGID NIPPLE THRU FURNACE APPLIANCE HOUSING. 2. SECURE GAS PIPING AT WATER HEATER. 3. VENT FROM FURNACE TO BE 2' ABOVE TOP OF COOLER WHEN WITHIN 10' OF INTAKE. 4. VENT FROM WATER HEATER TO HAVE MINIMUM 1" CLEARANCE FROM COMBUSTIBLES AND DRAFT HOOD TO BE INSTALLED CORRECTLY, PROVIDE 3-GALV SCREWS AT EACH JOINT. |