Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
MULTI FAMILY OTHER
Address NEW:
6939 E GOLF LINKS CI
Apply Date:
06/02/2006
Applicant:
PATRICIA SABALA
Description:
GAS: RECONNECT

Permit Reviews

Permit Number - T06PL00912
Permit Status: Expired
Permit Description: GAS: RECONNECT
Start Date Submittal Complete Date Status  
06/02/2006 PLUMBING 06/02/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06PL00912
Permit Status: Expired
Permit Description: GAS: RECONNECT
Total Outstanding Activity Conditions - 1
Date Name
06/02/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06PL00912
Permite Description: GAS: RECONNECT
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
PLUMBING - FINAL N/A Not Inspected
06/09/2006 PLUMBING - GAS RECONNECT N/A Partial Approval IVRS - Inspection :*
20 PSI TEST EXISTING PIPING OK
1. PROVIDE RIDGID NIPPLE THRU FURNACE APPLIANCE HOUSING.
2. SECURE GAS PIPING AT WATER HEATER.
3. VENT FROM FURNACE TO BE 2' ABOVE TOP OF COOLER WHEN WITHIN 10' OF INTAKE.
4. VENT FROM WATER HEATER TO HAVE MINIMUM 1" CLEARANCE FROM COMBUSTIBLES AND DRAFT HOOD TO BE INSTALLED CORRECTLY, PROVIDE 3-GALV SCREWS AT EACH JOINT.

Documents

File Name Document Type  
None DOCUMENTS VIEW