Permit: T06PL00836
Permit Details
Apply Date:
05/19/2006
Applicant:
ARIZONA PLUMBING SERVICES *C
Description:
REPLC: 40G GAS WTR HEATER (APA)
Contractors:
- ARIZONA PLUMBING SERVICES *C
Outstanding Activity Conditions
Permit Number - T06PL00836
Permit Status: Expired
Permit Description: REPLC: 40G GAS WTR HEATER (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/19/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06PL00836
Permite Description: REPLC: 40G GAS WTR HEATER (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/23/2006 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE SEDIMENT TRAP AT GAS INLET TO WATER HEATER. 2. PROVIDE COPPER PIPING FOR COLD SUPPLY TO WATER HEATER WITH ONLY (1) FLEX CONNECTIOR. USE OF METALLIC NIPPLE BETWEEN (2) NON-DIELECTRIC FLEXES IS NOT ACCEPTABLE. |