Permit: T06PL00469
Permit Details
Apply Date:
03/20/2006
Applicant:
GLENN JANDRAN
Description:
REPL: GAS LINE FROM METER TO TRAILER
Permit Reviews
Permit Number - T06PL00469
Permit Status: Expired
Permit Description: REPL: GAS LINE FROM METER TO TRAILER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/20/2006 | PLUMBING | 03/20/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06PL00469
Permit Status: Expired
Permit Description: REPL: GAS LINE FROM METER TO TRAILER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/20/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06PL00469
Permite Description: REPL: GAS LINE FROM METER TO TRAILER
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/26/2006 | PLUMBING - GAS PRESSURE TEST | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE A PRESSURE TEST W/ A 15 PSI GAUGE. USE A PIPE HANGER TO SUPPORT GAS PIPE. METAL STRAPPING IS NOT AN APPROVED PIPE SUPPORT. REMOVE AND CAP PIPE AT OLD PROPANE SERVICE CONNECTION TO HOME. WATER HEATER IS OK, BUT A WATER HEATER INSTALLED ON A WOOD SUBFLOOR REQUIRES A METAL DRAIN PAN TO PREVENT DAMAGE TO SUB-FLOOR WHICH COULD RESULT IN FIRE IF WH WERE TO SHIFT OR FALL THROUGH A DAMAGED FLOOR. |
| 05/26/2006 | PLUMBING - GAS PRESS TEST FNL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 05/26/2006 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |