Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
1051 E BILBY RD
Address NEW:
1051 E BILBY RD
Apply Date:
03/20/2006
Applicant:
GLENN JANDRAN
Description:
REPL: GAS LINE FROM METER TO TRAILER

Permit Reviews

Permit Number - T06PL00469
Permit Status: Expired
Permit Description: REPL: GAS LINE FROM METER TO TRAILER
Start Date Submittal Complete Date Status  
03/20/2006 PLUMBING 03/20/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06PL00469
Permit Status: Expired
Permit Description: REPL: GAS LINE FROM METER TO TRAILER
Total Outstanding Activity Conditions - 1
Date Name
03/20/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06PL00469
Permite Description: REPL: GAS LINE FROM METER TO TRAILER
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
05/26/2006 PLUMBING - GAS PRESSURE TEST N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE A PRESSURE TEST W/ A 15 PSI GAUGE.
USE A PIPE HANGER TO SUPPORT GAS PIPE.
METAL STRAPPING IS NOT AN APPROVED PIPE SUPPORT.
REMOVE AND CAP PIPE AT OLD PROPANE SERVICE CONNECTION TO HOME.
WATER HEATER IS OK, BUT A WATER HEATER INSTALLED ON A WOOD SUBFLOOR REQUIRES A METAL DRAIN PAN TO PREVENT DAMAGE TO SUB-FLOOR WHICH COULD RESULT IN FIRE IF WH WERE TO SHIFT OR FALL THROUGH A DAMAGED FLOOR.
05/26/2006 PLUMBING - GAS PRESS TEST FNL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/26/2006 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*

Documents

File Name Document Type  
None DOCUMENTS VIEW