Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Violatn
Type:
SINGLE FAMILY OTHER
Address:
1303 E EDISON ST
Apply Date:
12/12/2006
Applicant:
JANSON DONALD J & JUDITH A CP/RS
Description:
FLOODPLAIN USE PERMIT

Permit Reviews

Permit Number - T06OT03214
Permit Status: Violatn
Permit Description: FLOODPLAIN USE PERMIT
Start Date Submittal Complete Date Status  
12/12/2006 FLOODPLAIN 12/12/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06OT03214
Permit Status: Violatn
Permit Description: FLOODPLAIN USE PERMIT
Total Outstanding Activity Conditions - 1
Date Name
12/12/2006 December 12, 2006 FLOODPLAIN USE PERMIT NO. T06OT03214 RELATED PERMIT NO. T06CM06284 ADDRESS: 1303 E. Edison St. PROPERTY OWNER'S NAME: Donald Janson The applicant is authorized to use a portion of the flood hazard area in the City of Tucson on the property described as (legal description): MONTEREY AMENDED LOT 9 & W2 OF LOT 10 BLK 39 This permit is for the purpose of construction of detached garage within a mapped City of Tucson Flood Hazard Area. The applicant agrees to comply with the City of Tucson's Floodplain, Stormwater and Erosion Hazard Management Ordinance and the Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson's Floodplain, Stormwater and Erosion Hazard Management Ordinance and the Watercourse Amenities, Safety and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions shall apply to this permit. (Or refer to Chapter 26 page 35) 1. The top of the lowest finished floor (FFE) shall be elevated to a minimum 18 inches above highest adjacent natural grade. 2. Service facilities, such as electrical, heating and cooling equipment, shall be constructed at or above the same minimum elevation as the FFE and either be placed on flood proof materials or be adequately flood proofed. 3. A Building-Under-Construction Elevation Certificate, completed and certified by an Arizona Registered Land Surveyor, must be returned to the Engineering Division of the Development Services Department prior to the pouring of the concrete slab. A hold will be placed on the prior-to-slab inspection (P2S) until the Elevation Certificate has been returned and approved. 4. A Finished-Construction Elevation Certificate, completed and certified by an Arizona Registered Land Surveyor, must be returned to the Engineering Division of the Development Services Department prior to any final inspections. A hold will be placed on final inspections until the Elevation Certificate has been returned and approved. 5. All work shall be performed so that the amount of disturbance to the floodplain will be minimal. 6. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 7. This permit becomes invalid and is subject to additional floodplain review, if any required development permit(s) changes the configuration of the structure and or site development. 8. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Section. 9. Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Use Permit No. T06OT03214. For information please call 791-5550." (EXPIRATION DATE) Month: 12 Day: 12 Year: 2007 APPLICANT NAME: Donald Janson ADDRESS: 1303 E. Edison St. PHONE NO.: 520-290-1729 ________________ _____ DATE APPLICANT'S SIGNATURE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Documents

File Name Document Type  
None DOCUMENTS VIEW