Permit: T06OT00050
Permit Details
Apply Date:
01/06/2006
Applicant:
FLUORESCO LIGHTING MAINTENANCE**C
Description:
10384
Contractors:
- FLUORESCO LIGHTING MAINTENANCE**C
Completed Inspections
Permit Status: Final
Permit Number: T06OT00050
Permit Description: 10384
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/09/2006 | SIGN SITE REVIEW | JSONKIN | Approved | |
| 01/09/2006 | SIGN SITE REVIEW | JSONKIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 11/15/2006 | SIGN EXCAVATION | JSONKIN | Approved | IVRS - Inspection :*MAKE SURE SIGN SETBACK WILL BE AS PER APPROVED PLANS |
| 08/06/2007 | SIGN SHOP | RHOLLAND | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. MARKING LABELS NEEDED FOR "EMICH" 2. SWITCH TO BE CAPABLE OF BEING LOCKED OUT 3. GROUND JUNCTION BOX 4. USE CORRECT SIZED TRANSFORMER ENCLOSURE COVERS 5. PLEASE PROVIDE ACCESS TO LETTERS & LOGO MONUMENT: 1. PLEASE VERIFY GROUND IN ELECTRODE SYSTEM FOR TRANSFORMER 2. A MARKING LABEL IS NEEDED -- 600.4 3. A SWITCH IS NEEDED 606.6 4. SPLICES TO BE LISTED FOR WET LOCATION |
| 08/06/2007 | SIGN ELECTRIC | RHOLLAND | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 09/03/2008 | SIGN INSPECTION | JYBARRA | Approved | |
| 04/13/2009 | PERMIT FINALED | BFLORES | Approved |