Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
7252 S RINCON RIDGE DR
Apply Date:
05/16/2006
Applicant:
RITE WAY VENTILATING CO , *C
Description:
INSTALL: 2 TON PACKAGE UNIT (APA)
Contractors:
  • RITEWAY VENTILATING CO. *C*

Outstanding Activity Conditions

Permit Number - T06ME00249
Permit Status: Expired
Permit Description: INSTALL: 2 TON PACKAGE UNIT (APA)
Total Outstanding Activity Conditions - 1
Date Name
05/16/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06ME00249
Permite Description: INSTALL: 2 TON PACKAGE UNIT (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
06/19/2006 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
DISCONNECTS MOUNTED ON SERVICE PANEL FOR COIL REMOVED. RELOCATE.
MARK THE UNIT DATA PLATE W/PROPER HEAT STRIP INSTALLED & FUSE ACCORDINGLY.
PROVIDE A COVER OVER EXPOSED FLEX DUCT & CANVAS CONNECTOR.

Documents

File Name Document Type  
T06ME00249 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW