Permit: T06EL02067
Permit Details
Apply Date:
10/13/2006
Applicant:
ANNA PADILLA
Description:
ELEC RECONNECT
Outstanding Activity Conditions
Permit Number - T06EL02067
Permit Status: Final
Permit Description: ELEC RECONNECT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/13/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06EL02067
Permit Description: ELEC RECONNECT
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/13/2006 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. STILL SOME SWITCHES, COVERS MISSING NO SMOKE DETECTOR OR LIGHT FIXTURE IN NORTHEAST BEDROOM. 2. NO COMPIANCE IN BACK OF HOUSE AT SERVICE AREA HAVE ELECTRICIAN CALL RAY M. OR DAN SANTA CRUZ 791-5550 EXT.1136 |
| 11/14/2006 | ELECTRIC - RECONNECT | RMAJUTA | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. SUP PNL FALLING OFF WALL; IMPROPER FEED, ADDED W/O PERMIT - DEAD FRONT COVER MISSING. 2. J-BOX BY SERVICE TO SMALL NEEDS TO BE WP 3. REMOVE GROUND WIRE FROM SUB-PNL SERVICE ALREADY GROUNDED. 4. REPAIR BEHIND WATER DIST. 5. CORRECT KIT EX WIRING 6. JD'S IN BEDROOMS 7. COVER ELECT BOX IN HALL 8. PUTKONERS ON W/SW'S & RECEPTS 9. CORRECT SWITCH WIRING AT MID BEDRM & INSTALL LIGHT 10. MISSING LT. BDRM HAVE ELECT REVIEW WIRING & CORRECT & READY FOR OCCUPANCY AGAIN. 1. NOT SUPPORTED CORRECTLY & PNL LOCKED. 2. NOT ADDRESSED |
| 08/20/2009 | TEP CLEARANCE - PM | JWEATHER | Approved | RECN CLEARED PER R. MAJUTA |
| 08/20/2009 | PERMIT FINALED | JWEATHER | Approved |