Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
1908 N SANTA ROSA AV
Apply Date:
08/16/2006
Applicant:
ESSNER JAMES
Description:
200amp upgrade
Contractors:
  • ESSNER ELECTRIC

Outstanding Activity Conditions

Permit Number - T06EL01624
Permit Status: Expired
Permit Description: 200amp upgrade
Total Outstanding Activity Conditions - 1
Date Name
08/16/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06EL01624
Permite Description: 200amp upgrade
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/11/2006 ELECTRIC - FINAL N/A Denied 1) MAKE SURE WATER AND GAS PIPES ARE PROPERLY BONDED
2) INSTALL FLASHING, STRUT CLAMP & BRACE FOR MAST
3) SERVICE NEED MINIMUM 36" FRONT WORKING SPACE, RIGHT NOW A/C UNIT IS BLOCKING THAT AREA
4) SECURE BOND AND GROUNDING ELECTRODE CONDUCTOR TO STRUCTURE

Completed Inspections

Permit Status: Expired
Permit Number: T06EL01624
Permit Description: 200amp upgrade
Total Completed Inspections - 1
Date Description Inspector Results Comments
09/12/2006 TEP CLEARANCE - AM JWEATHER Approved INCR CLEARED PER C. CLEMENS

Documents

File Name Document Type  
T06EL01624 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW