Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
2574 N CAMPBELL AV
Apply Date:
12/28/2006
Applicant:
SANTOS FRANCIS
Description:
TI:RESTAURANT
Contractors:
  • CIREROL BUILDERS L L C

Permit Reviews

Permit Number - T06CM06545
Permit Status: C of o
Permit Description: TI:RESTAURANT
Start Date Submittal Complete Date Status  
02/07/2007 POST 3RD PARTY REVIEW 02/14/2007 COMPLETED Review Details
02/14/2007 RESUBMITTAL 03/08/2007 COMPLETED Review Details
03/08/2007 3RD PARTY REVIEW-REVISION/OTHER 03/12/2007 COMPLETED Review Details
12/28/2006 COMMERCIAL TI 12/28/2006 COMPLETED Review Details
12/28/2006 3RD PARTY REVIEW-COMMERCIAL TI 02/07/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM06545
Permit Status: C of o
Permit Description: TI:RESTAURANT
Total Outstanding Activity Conditions - 1
Date Name
12/28/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM06545
Permit Description: TI:RESTAURANT
Total Completed Inspections - 30
Date Description Inspector Results Comments
02/21/2007 FRAMING JBURGE Approved IVRS - Inspection :*
OK TO SHEETROCK
03/01/2007 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
04/03/2007 NPPO - FINAL ACONNOR Approved N/A
04/03/2007 LANDSCAPE - FINAL ACONNOR Approved N/A
04/05/2007 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
04/20/2007 MECHANICAL - HOOD SYSTEMS JMILITEL Approved IVRS - Inspection :*
SUPPORT EVAP. COOLER WATER LINES EVERY 6'
SEAL SCREW HEADS & SEAMS ON STAINLESS STEEL UNDER HOOD. ADD STAINLESS ON WALL RIGHT SIDE OF HOOD.
04/20/2007 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection :*
04/20/2007 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
04/23/2007 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
04/23/2007 ENGINEERING - FINAL MRUSSO Approved
04/24/2007 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
AIR BALANCE OK
OK FOR FINAL
04/24/2007 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :*
NOTE: ALL 120V 15 & 20 AMP
RECEPTACLES IN KITCHEN TO HAVE GFI PROTECTION --
NEC 210.8
04/24/2007 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
04/24/2007 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
04/24/2007 PLUMBING - GAS PRESS TEST FNL BBENEDON Approved IVRS - Inspection :*
04/24/2007 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :*
04/24/2007 ELECTRIC - RECONNECT CCLEMENS Approved IVRS - Inspection :*
04/24/2007 ELECTRIC - CONSTRUCTION POWER CCLEMENS Approved IVRS - Inspection :*
04/24/2007 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
04/24/2007 ELECTRIC - ABOVE CEILING CCLEMENS Approved IVRS - Inspection :*
04/24/2007 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
04/24/2007 ELECTRIC - INTERMEDIATE IVR USER Approved IVRS - RI canceled
04/25/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved
04/25/2007 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
OK C OF O
04/25/2007 PLUMBING - PRE SLAB RMYERS Approved
05/04/2007 FIRE - KITCHEN EXH HOOD FINAL LLAKEY Approved
05/04/2007 HEALTH DEPT - FINAL 724-7908 RPEYTON Approved
06/08/2007 PERMIT FINALED LJACKSON Approved
06/08/2007 FIRE - FINAL LLAKEY Approved
06/08/2007 FIRE SPKLR - FINAL LLAKEY Approved

Documents

File Name Document Type  
T06CM06545 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW
None CERT OF OCC VIEW
6545-01-0001-01-REVISION001.TIF CONSTRPLANS VIEW
6545-01-0001-01-REVISION002.TIF CONSTRPLANS VIEW
6545-01-0001-01-REVISION2001.TIF CONSTRPLANS VIEW
6545-01-0001-01-REVISION2002.TIF CONSTRPLANS VIEW
6545-01-0001-01-REVISION2003.TIF CONSTRPLANS VIEW
6545-01-0001-01-REVISION2004.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL001.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL002.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL003.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL004.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL005.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL006.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL007.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL008.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL009.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL010.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL011.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL012.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL013.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL014.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL015.TIF CONSTRPLANS VIEW
6545-01-0001-01-ORIGINAL016.TIF CONSTRPLANS VIEW
BONDRELEASE.TIF DOCUMENTS VIEW
FRANKIE1.JPG SIGNS VIEW
FRANKIE2.JPG SIGNS VIEW