Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T06CM04067
Permit Details
Apply Date:
07/11/2006
Applicant:
SEPASSI REZA & MALEKNIAZI NAHID JT/RS
Description:
ADDITION:BATHROOM:BEDROOM R1 Add GFCI to kitchen
Permit Reviews
Permit Number - T06CM04067
Permit Status: Final
Permit Description: ADDITION:BATHROOM:BEDROOM
R1 Add GFCI to kitchen
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/11/2006 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 08/08/2006 | COMPLETED |
08/10/2006 | OTHER | 08/23/2006 | COMPLETED |
09/20/2006 | REVISION - - 1ST | 09/20/2006 | COMPLETED |
10/27/2006 | REVISION - - 2ND | 10/27/2006 | ACTIVE |
Outstanding Activity Conditions
Permit Number - T06CM04067
Permit Status: Final
Permit Description: ADDITION:BATHROOM:BEDROOM
R1 Add GFCI to kitchen
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/11/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06CM04067
Permit Description: ADDITION:BATHROOM:BEDROOM
R1 Add GFCI to kitchen
Total Completed Inspections - 19
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/18/2006 | PLUMBING - ROUGH, SOIL | RCAMACHO | Approved | IVRS - Inspection :* |
09/21/2006 | BUILDING PRE-SLAB | RCAMACHO | Approved | IVRS - Inspection :* |
09/21/2006 | EXCAVATION/LAYOUT REBAR & ZON | RCAMACHO | Approved | IVRS - Inspection :* |
10/02/2006 | EXT METAL CLIPS/EXT SHEATHING | RCAMACHO | Approved | IVRS - Inspection :* |
10/05/2006 | ROOF NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
10/31/2006 | U VALUE FOR WINDOW | RCAMACHO | Approved | IVRS - Inspection :* |
10/31/2006 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
10/31/2006 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
10/31/2006 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
10/31/2006 | FRAMING | RCAMACHO | Approved | IVRS - Inspection :* |
11/09/2006 | SHEET ROCK NAILING | CRUIZ | Approved | IVRS - Inspection :* |
12/15/2006 | PLUMBING - SEWER HCS CONNECT | RCAMACHO | Approved | IVRS - Inspection :* |
12/15/2006 | ELECTRIC - RECONNECT | RCAMACHO | Approved | IVRS - Inspection :* |
12/18/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | RECN CLEARED PER R. CAMACHO |
12/28/2006 | BUILDING - FINAL | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO CAULK AND SEAL AROUND TOILET BASE 2) EXHAUST FAN KITCHEN MISSING 3) NEED 90 DEGREE ELBOW IN W/H RELIEF DRAIN 4) A/C UNIT DRAIN NEEDS TO TERMINATE ON GROUND 5) NO LADDER TO CLIMB ON ROOF TO INSPECT A/C UNIT 6) STOVE NEEDS ANTI-TIP DEVICE 7) STOPPED INSPECTION |
12/28/2006 | MECHANICAL - FINAL | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/28/2006 | PLUMBING - FINAL | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/28/2006 | ELECTRIC - FINAL | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
01/03/2007 | PERMIT FINALED | JWEATHER | Approved |