Permit: T06CM03894
Permit Details
Apply Date:
07/03/2006
Applicant:
D R HORTON HOMES *C
Description:
SFR TD # 16-63-57 T06-M0056
Contractors:
- D R HORTON HOMES *C
Permit Reviews
Permit Number - T06CM03894
Permit Status: C of o
Permit Description: SFR TD # 16-63-57 T06-M0056
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/03/2006 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/06/2006 | COMPLETED |
08/04/2006 | REVISION - - 1ST | 08/04/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM03894
Permit Status: C of o
Permit Description: SFR TD # 16-63-57 T06-M0056
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/03/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM03894
Permit Description: SFR TD # 16-63-57 T06-M0056
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2006 | PLUMBING - YARD WTR LINE/TEST | WNORTH | Approved | NO PRESSURE ON LINE |
09/26/2006 | PLUMBING - SEWER HCS CONNECT | WNORTH | Approved | IVRS - Inspection :* |
09/26/2006 | PLUMBING - ROUGH, SOIL | WNORTH | Approved | IVRS - Inspection :* |
10/06/2006 | ELECTRIC - UNDERGROUND | RFREIDIN | Approved | IVRS - Inspection :* |
10/06/2006 | ELECTRIC - UFER | RFREIDIN | Approved | IVRS - Inspection :* |
10/06/2006 | BUILDING PRE-SLAB | RFREIDIN | Approved | IVRS - Inspection :* |
10/06/2006 | STEM WALL/RETAINING WALL | RFREIDIN | Approved | IVRS - Inspection :* |
10/06/2006 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | IVRS - Inspection :* |
11/29/2006 | EXT METAL CLIPS/EXT SHEATHING | WNORTH | Approved | IVRS - Inspection :* 1) NAILING OK 2) OK TO WRAP 3) ADD RED HEADS AT BLUE X'S |
11/29/2006 | ROOF NAILING | WNORTH | Approved | IVRS - Inspection :* |
12/11/2006 | ELECTRIC - TEMPORARY SERVICE | WNORTH | Approved | IVRS - Inspection :* |
12/11/2006 | ELECTRIC - CABLE DROP | WNORTH | Approved | IVRS - Inspection :* |
12/12/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER W. NORTH |
12/26/2006 | FRAMING | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) AB'S AT FRONT ROOM SHEAR EACH SIDE OF WINDOW 2) TIGHTEN A.B.'S AT 1ST FLOOR BATH 3) BANG PLATE HALL 1ST FLOOR ROMEX 4) 60 DEGREE PITCH ON H20 HTR FLUE 5) BROKEN STUD GARAGE TO HOUSE 6) FLOOR TRUSS NOT AT 24" ON CENTER 7) FINISH 2ND FLOOR SOIL NEED DWV TEST 8) BLOCK MECH LAUNDRY 9) MAKE SURE TRUSS HANGERS ARE NAILED TO GIRDER, ROOF 10) LATHE NOT COMPLETE FRONT |
12/26/2006 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/26/2006 | PLUMBING - GAS PRESSURE TEST | RFREIDIN | Approved | IVRS - Inspection :* |
12/26/2006 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/26/2006 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/26/2006 | STUCCO MESH | RFREIDIN | Approved | IVRS - Inspection :* |
01/12/2007 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
03/21/2007 | PLUMBING - FINAL | WLAHR | Approved | IVRS - Inspection :* |
03/21/2007 | ELECTRIC - FINAL | WLAHR | Approved | IVRS - Inspection :* |
03/27/2007 | MECHANICAL - FINAL | WLAHR | Approved | IVRS - Inspection :* |
03/27/2007 | BUILDING - FINAL | WLAHR | Approved | IVRS - Inspection :* |
03/30/2007 | PERMIT FINALED | JWEATHER | Approved |