Permit: T06CM02190
Permit Details
Status:
Expired
Type:
COMMERCIAL ADDITION
Address:
11400 W SNYDER HILL RD
Address NEW:
11400 W SNYDER HILL RD
Apply Date:
04/17/2006
Applicant:
DOROTHY DOLAN
Description:
INSTALL: WELL (TUCSON WATER EQUIP WELL AV-026A) - 11' x 11' MASONRY WALLS W/ REINFORCED CONCRETE ROOF CONTROL STRUCTURE. - 105 LF OF MASONRY FENCE WALL. - 5000 GALLON HYDROPNEUMATIC PRESSURE WATER TANK. - PUMP AND MOTOR AT WELL.
Contractors:
- P AND H CONTRACTING INC ,
Permit Reviews
Permit Number - T06CM02190
Permit Status: Expired
Permit Description: INSTALL: WELL (TUCSON WATER EQUIP WELL AV-026A)
- 11' x 11' MASONRY WALLS W/ REINFORCED CONCRETE ROOF CONTROL STRUCTURE.
- 105 LF OF MASONRY FENCE WALL.
- 5000 GALLON HYDROPNEUMATIC PRESSURE WATER TANK.
- PUMP AND MOTOR AT WELL.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/17/2006 | PLANS OK TO SUBMIT - COMM | 04/17/2006 | COMPLETED |
| 05/10/2006 | COMMERCIAL-BLDG/FIRE/ZONING/ENG | 06/19/2006 | COMPLETED |
| 06/21/2006 | RESUBMITTAL | 07/25/2006 | COMPLETED |
| 07/13/2006 | OTHER | 07/13/2006 | COMPLETED |
| 07/25/2006 | RESUBMITTAL | 08/01/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM02190
Permit Status: Expired
Permit Description: INSTALL: WELL (TUCSON WATER EQUIP WELL AV-026A)
- 11' x 11' MASONRY WALLS W/ REINFORCED CONCRETE ROOF CONTROL STRUCTURE.
- 105 LF OF MASONRY FENCE WALL.
- 5000 GALLON HYDROPNEUMATIC PRESSURE WATER TANK.
- PUMP AND MOTOR AT WELL.
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 04/17/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 05/11/2006 | SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. |
| 05/11/2006 | SPECIAL INSPECTION FOR CONCRETE IS REQUIRED.. |
| 05/11/2006 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
| 05/11/2006 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T06CM02190
Permit Description: INSTALL: WELL (TUCSON WATER EQUIP WELL AV-026A)
- 11' x 11' MASONRY WALLS W/ REINFORCED CONCRETE ROOF CONTROL STRUCTURE.
- 105 LF OF MASONRY FENCE WALL.
- 5000 GALLON HYDROPNEUMATIC PRESSURE WATER TANK.
- PUMP AND MOTOR AT WELL.
Total Completed Inspections - 14
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2006 | ELECTRIC - UFER | GDABBS | Approved | IVRS - Inspection :* |
| 09/12/2006 | REINFORCED MASONRY PRE-GROUT | AALEGRIA | Approved | IVRS - Inspection :* CONTROL BUILDING TOP OUT DETAIL C ON SHEET 8 2#4 BOND BEAM #4 DOWL @ 24" O.C 12"/12" |
| 09/12/2006 | STEM WALL/RETAINING WALL | AALEGRIA | Approved | 2ND LIFT TOPOUT DETAIL 5/1 ON SHEET 5 2#4 ON BOND BEAM |
| 10/05/2006 | ROOF NAILING | AALEGRIA | Approved | IVRS - Inspection :* REINFORCED FOR CONCRETE ROOF #4 @ 9" O.C EACH WAY AND CONNECTION WITH #4 DOWEL @ 24" O.C AND WALL CMU. DRIP 1" WIDE X 1" DEEP AND CLEAR SPACE OF 2" FROM EDGE SHEET 8 & BUILDING SECTION AND DETAILS. |
| 10/05/2006 | FRAMING | AALEGRIA | Approved | IVRS - Inspection :* |
| 12/05/2006 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* |
| 12/19/2006 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 12/19/2006 | ELECTRIC - OUTDOOR LIGHTING | DSANTACR | Approved | IVRS - Inspection :* |
| 12/27/2006 | BUILDING - FINAL | AALEGRIA | Approved | IVRS - Inspection :* NOTE: IN COMPLIANCE WITH APPROVED PLANS AND SPEC. |
| 12/27/2006 | MECHANICAL - FINAL | AALEGRIA | Approved | IVRS - Inspection :* |
| 12/28/2006 | ELECTRIC - CABLE DROP | DSANTACR | Approved | |
| 12/28/2006 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | |
| 12/28/2006 | EXCAVATION/LAYOUT REBAR & ZON | AALEGRIA | Approved | |
| 12/28/2006 | BUILDING PRE-SLAB | AALEGRIA | Approved |