Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL ADDITION
Address NEW:
11400 W SNYDER HILL RD
Apply Date:
04/17/2006
Applicant:
DOROTHY DOLAN
Description:
INSTALL: WELL (TUCSON WATER EQUIP WELL AV-026A) - 11' x 11' MASONRY WALLS W/ REINFORCED CONCRETE ROOF CONTROL STRUCTURE. - 105 LF OF MASONRY FENCE WALL. - 5000 GALLON HYDROPNEUMATIC PRESSURE WATER TANK. - PUMP AND MOTOR AT WELL.
Contractors:
  • P AND H CONTRACTING INC ,

Permit Reviews

Permit Number - T06CM02190
Permit Status: Expired
Permit Description: INSTALL: WELL (TUCSON WATER EQUIP WELL AV-026A) - 11' x 11' MASONRY WALLS W/ REINFORCED CONCRETE ROOF CONTROL STRUCTURE. - 105 LF OF MASONRY FENCE WALL. - 5000 GALLON HYDROPNEUMATIC PRESSURE WATER TANK. - PUMP AND MOTOR AT WELL.
Start Date Submittal Complete Date Status  
04/17/2006 PLANS OK TO SUBMIT - COMM 04/17/2006 COMPLETED Review Details
05/10/2006 COMMERCIAL-BLDG/FIRE/ZONING/ENG 06/19/2006 COMPLETED Review Details
06/21/2006 RESUBMITTAL 07/25/2006 COMPLETED Review Details
07/13/2006 OTHER 07/13/2006 COMPLETED Review Details
07/25/2006 RESUBMITTAL 08/01/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM02190
Permit Status: Expired
Permit Description: INSTALL: WELL (TUCSON WATER EQUIP WELL AV-026A) - 11' x 11' MASONRY WALLS W/ REINFORCED CONCRETE ROOF CONTROL STRUCTURE. - 105 LF OF MASONRY FENCE WALL. - 5000 GALLON HYDROPNEUMATIC PRESSURE WATER TANK. - PUMP AND MOTOR AT WELL.
Total Outstanding Activity Conditions - 5
Date Name
04/17/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
05/11/2006 SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
05/11/2006 SPECIAL INSPECTION FOR CONCRETE IS REQUIRED..
05/11/2006 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
05/11/2006 SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED.

Completed Inspections

Permit Status: Expired
Permit Number: T06CM02190
Permit Description: INSTALL: WELL (TUCSON WATER EQUIP WELL AV-026A) - 11' x 11' MASONRY WALLS W/ REINFORCED CONCRETE ROOF CONTROL STRUCTURE. - 105 LF OF MASONRY FENCE WALL. - 5000 GALLON HYDROPNEUMATIC PRESSURE WATER TANK. - PUMP AND MOTOR AT WELL.
Total Completed Inspections - 14
Date Description Inspector Results Comments
08/24/2006 ELECTRIC - UFER GDABBS Approved IVRS - Inspection :*
09/12/2006 REINFORCED MASONRY PRE-GROUT AALEGRIA Approved IVRS - Inspection :*
CONTROL BUILDING TOP OUT DETAIL C ON SHEET 8
2#4 BOND BEAM

#4 DOWL @ 24" O.C 12"/12"
09/12/2006 STEM WALL/RETAINING WALL AALEGRIA Approved 2ND LIFT TOPOUT DETAIL 5/1 ON SHEET 5 2#4 ON BOND BEAM
10/05/2006 ROOF NAILING AALEGRIA Approved IVRS - Inspection :*
REINFORCED FOR CONCRETE ROOF
#4 @ 9" O.C EACH WAY AND CONNECTION WITH #4 DOWEL @ 24" O.C AND WALL CMU.
DRIP 1" WIDE X 1" DEEP AND CLEAR SPACE OF 2" FROM EDGE
SHEET 8 & BUILDING SECTION AND DETAILS.
10/05/2006 FRAMING AALEGRIA Approved IVRS - Inspection :*
12/05/2006 ELECTRIC - UNDERGROUND DSANTACR Approved IVRS - Inspection :*
12/19/2006 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
12/19/2006 ELECTRIC - OUTDOOR LIGHTING DSANTACR Approved IVRS - Inspection :*
12/27/2006 BUILDING - FINAL AALEGRIA Approved IVRS - Inspection :*
NOTE: IN COMPLIANCE WITH APPROVED PLANS AND SPEC.
12/27/2006 MECHANICAL - FINAL AALEGRIA Approved IVRS - Inspection :*
12/28/2006 ELECTRIC - CABLE DROP DSANTACR Approved
12/28/2006 ELECTRIC - INTERMEDIATE DSANTACR Approved
12/28/2006 EXCAVATION/LAYOUT REBAR & ZON AALEGRIA Approved
12/28/2006 BUILDING PRE-SLAB AALEGRIA Approved

Documents

File Name Document Type  
FLOODPLAIN.TIF DOCUMENTS VIEW
STRUCCALCS.TIF DOCUMENTS VIEW
STRUCCALCS2.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW