Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
DUPLEX NEW
Address NEW:
3331 E BERMUDA ST #07
Apply Date:
03/29/2006
Applicant:
N/A
Description:
NEW DUPLEX
Contractors:
  • INOVATIVE CUSTOM HOMES AND DESIGN INC

Permit Reviews

Permit Number - T06CM01767
Permit Status: C of o
Permit Description: NEW DUPLEX
Start Date Submittal Complete Date Status  
01/11/2008 3RD PARTY REVIEW-REVISION/OTHER 01/14/2008 COMPLETED Review Details
03/29/2006 PLANS OK TO SUBMIT - RES 03/29/2006 COMPLETED Review Details
03/29/2006 3RD PARTY REVIEW-RESIDENTIAL 07/05/2006 COMPLETED Review Details
07/05/2006 POST 3RD PARTY REVIEW 11/08/2006 COMPLETED Review Details
08/31/2007 3RD PARTY REVIEW-REVISION/OTHER 09/04/2007 COMPLETED Review Details
12/07/2006 RESUBMITTAL 03/20/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM01767
Permit Status: C of o
Permit Description: NEW DUPLEX
Total Outstanding Activity Conditions - 1
Date Name
03/29/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM01767
Permit Description: NEW DUPLEX
Total Completed Inspections - 26
Date Description Inspector Results Comments
06/20/2007 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
OK TO COVER UNDERGROUND SUBJECT TO ARCHITECTS APPROVAL OF PEX
07/06/2007 ELECTRIC - UFER CCLEMENS Approved IVRS - Inspection :*
BOTH EAST BUILDINGS & N.W BUILDING
07/06/2007 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
07/06/2007 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
08/14/2007 ROOF NAILING JBURGE Approved IVRS - Inspection :*
OK TO DRY IN
09/20/2007 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
1) OK TO COVER SHEATHING
11/30/2007 PLUMBING - YARD WTR LINE/TEST BBENEDON Approved IVRS - Inspection :*
RECALL WATER FOR FINAL CONNECTIONS
11/30/2007 PLUMBING - SEWER HCS CONNECT BBENEDON Approved IVRS - Inspection :*
12/21/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
1) PROVIDE A SCREW IN EXHAUST DUCT CONNECTION TO FAN OUTLET
2) PROVIDE CLEARANCE AROUND WATER HEATER VENTS FROM COMBUSTIBLES
3) PROVIDE INSULATION SHEILDS AROUND FIREPLACE AND WATER HEATER VENTS
12/21/2007 FRAMING RFREIDIN Approved IVRS - Inspection :*
1) PLAN CALLS FOR TWO LAYERS 1/2 X EACH SIDE-MOVE PARTITIONS AT INTERSECTING WALLS AND BLOCK FOR BACKING WHERE NEEDED AND HAVE PLAN REVISED
12/21/2007 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection :*
12/21/2007 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
12/21/2007 U VALUE FOR WINDOW RFREIDIN Approved IVRS - Inspection :*
12/21/2007 STUCCO MESH RFREIDIN Approved IVRS - Inspection :*
12/21/2007 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection :*
12/21/2007 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection :*
12/21/2007 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
12/24/2007 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER R. FREIDINGER
01/25/2008 SHEET ROCK NAILING DWALKER Approved IVRS - Inspection :*
06/27/2008 MECHANICAL - HOODS DWALKER Approved
06/27/2008 BUILDING ABOVE CEILING DWALKER Approved
06/27/2008 MECHANICAL - FINAL DWALKER Approved IVRS - Inspection :*
06/27/2008 PLUMBING - FINAL DWALKER Approved IVRS - Inspection :*
06/27/2008 ELECTRIC - FINAL DWALKER Approved IVRS - Inspection :*
06/27/2008 BUILDING - FINAL DWALKER Approved IVRS - Inspection :*
07/02/2008 FIRE - FINAL LTHOMAS Approved

Documents

File Name Document Type  
C OF O_07-10-2008.TIF CERT OF OCC VIEW
T06CM01767_001.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW