Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T06CM01029
Permit Details
Status:
Withdrwn
Type:
COMMERCIAL NEW
Address:
1974 E SILVERLAKE RD
Address NEW:
1974 E SILVERLAKE RD
Apply Date:
02/21/2006
Applicant:
N/A
Description:
SHELL BUILDING INDUSTRIAL
Architects:
- ALLEVA, ANSELMO FRANCISCO
Contractors:
- RIO WEST DEVELOPMENT AND CONSTRU
Permit Reviews
Permit Number - T06CM01029
Permit Status: Withdrwn
Permit Description: SHELL BUILDING INDUSTRIAL
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/21/2006 | PLANS OK TO SUBMIT - 3RD PARTY | 02/24/2006 | COMPLETED |
| 02/24/2006 | 3RD PARTY REVIEW-COMMERCIAL | 05/30/2006 | COMPLETED |
| 05/30/2006 | POST 3RD PARTY REVIEW | 06/05/2006 | COMPLETED |
| 06/05/2006 | POST 3RD PARTY REVIEW | 06/07/2006 | COMPLETED |
| 06/07/2006 | RESUBMITTAL | 06/13/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM01029
Permit Status: Withdrwn
Permit Description: SHELL BUILDING INDUSTRIAL
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 02/21/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 05/30/2006 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
| 05/30/2006 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
Outstanding Inspections
Permit Status: Withdrwn
Permit Number: T06CM01029
Permite Description: SHELL BUILDING INDUSTRIAL
Total Outstanding Inspections - 14
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| FRAMING | N/A | Not Inspected | ||
| U VALUE FOR WINDOW | N/A | Not Inspected | ||
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - INTERMEDIATE | N/A | Not Inspected | ||
| ELECTRIC - CABLE DROP | N/A | Not Inspected | ||
| ELECTRIC - TEMPORARY SERVICE | N/A | Not Inspected | ||
| ELECTRIC - OUTDOOR LIGHTING | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| OUTDOOR LIGHTING FINAL | N/A | Not Inspected | ||
| FIRE - FINAL | N/A | Not Inspected | ||
| 01/05/2007 | ELECTRIC - UFER | N/A | Partial Approval | IVRS - Inspection :* SEE NOTE FOR T06CM01028 - 1980 E |
| 02/16/2007 | REINFORCED MASONRY PRE-GROUT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* REQUEST THE APPROPRIATE INSPECTION IN ACCORDANCE WITH ACTIVITY NUMBER. RESUBMIT PLANS FOR COMPLIANCE WITH JOB ON SITE REGARDING 2 BUILDING ON ONE AND 2 DIFFERENT ACTIVITIES FOR ALL WORK ANY CHANCES MADE AT THIS POINT NEED TO BE REVIEWED BY DSD CITY OF TUCSON |
| 03/28/2007 | ROOF NAILING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* SAME AS 1956 E SILVERLAKE RD CORRECTION LEFT |
| 11/28/2006 | EXCAVATION/LAYOUT REBAR & ZON | N/A | Not ready for Inspection | IVRS - Inspection :* |