Permit: T06CM01008
Permit Details
Apply Date:
02/17/2006
Applicant:
YTURRALDE DAMON
Description:
NEW GAS PACK UNIT
Outstanding Activity Conditions
Permit Number - T06CM01008
Permit Status: Expired
Permit Description: NEW GAS PACK UNIT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/17/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06CM01008
Permite Description: NEW GAS PACK UNIT
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/13/2006 | PLUMBING - GAS PRESSURE TEST | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* PRESSURE TEST REQUIRED ADD REPLACEMENT OF WATER HEATER TO PERMIT. INDOOR APPLIANCES INSTALLED OUTDOORS REQUIRE PROTECTION. OLD FLUE PIPING THAT IS NOT BEING USED SHALL BE REMOVED. GAS PIPING ON ROOF REQUIRES SUPPORT OPEN SEWER PIPING AT WH LOCATION MUST BE TERMINATE ABOVE ROOF. METHANE GAS DOES BURN. |
| 03/14/2006 | MECHANICAL - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection :* 1) WANT TO SPEAK TO MECHANICAL CONTRACTOR ABOUT: FLEX DUCT IN ATTIC-WHAT R FACTOR IS FLEX ? 2) IS FLEX DUCT INSIDE OF HORIZONTAL DUCT ABOVE ROOF ? 3) CONDENSATE PIPING 4) EXPOSED CONTROL WIRING 5) IS COMB. UNIT BEING REPAIRED ? |
| 03/14/2006 | MECHANICAL - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* |