Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY NEW
Apply Date:
02/09/2006
Applicant:
JOSEPH SMITH
Description:
NEW SFR
Contractors:
  • GOLDEN STAR PROPERTIES INC

Permit Reviews

Permit Number - T06CM00851
Permit Status: Expired
Permit Description: NEW SFR
Start Date Submittal Complete Date Status  
02/09/2006 PLANS OK TO SUBMIT - RES 02/16/2006 COMPLETED Review Details
02/16/2006 RESIDENTIAL BLDG/WWM 04/26/2006 COMPLETED Review Details
05/15/2006 RESUBMITTAL 05/25/2006 COMPLETED Review Details
06/06/2006 RESUBMITTAL 06/21/2006 COMPLETED Review Details
06/21/2006 RESUBMITTAL 06/27/2006 COMPLETED Review Details
07/10/2006 RESUBMITTAL 07/20/2006 COMPLETED Review Details
07/26/2006 RESUBMITTAL 07/26/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM00851
Permit Status: Expired
Permit Description: NEW SFR
Total Outstanding Activity Conditions - 2
Date Name
02/09/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
06/19/2006 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06CM00851
Permite Description: NEW SFR
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
REINFORCED MASONRY PRE-GROUT N/A Not Inspected
12/28/2007 BUILDING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. COMPLETE GRADING TO SLOPE FROM HOUSE
2. CLEAN OUT DEBRIS UNDER FIREPLACE
3. FIREPLACE COVER DOESN'T LATCH LEFT SIDE
4. IDENTIFY BREAKERS MORE THAN GEN'L LIGHTS AND RECEPTS
5. REMOVE AND COVER RECEPTACLES UNDER BREAKFAST BAR
6. COMPLETE WIRING STOVE HOOD
7. EXTERIOR LIGHTS TO COMPLY WITH DARK SKY ORDINANCES
04090 - MECHANICAL
8. BOTH FURNACES
RAISE VENT ON CONDENSATE DRAIN HIGHER THAN SECONDARY DRAIN. INSTALL SAFETY CUT OFF SWITCH OR SECONDARY DRAIN.
03090
9. SECURE DISHWASHER DRAIN LINE TO UNDER SIDE OF COUNTER
10. COMPLETE DRAIN POWER ROOM AND MASTER BATH AT LAVS
11. NEED ATTIC ACCESS (LADDER) TO CHECK FURNACE IN ATTIC
12. IS INSULATION EFFECTIVE WHEN THERE IS AN UNINSULATED WALL ABOVE NORTH DOCK AREA?
13. NEED TO SEE APPROVAL OF SEPTIC SYSTEM BY PIMA COUNTY
12/28/2007 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/28/2007 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/28/2007 LANDSCAPE - FINAL N/A Denied 3.7.2.7 Plant Cover/Dust Control. All disturbed, grubbed, graded, or bladed areas not otherwise improved shall be landscaped, reseeded, or treated with an inorganic or organic ground cover to help reduce dust pollution.

Completed Inspections

Permit Status: Expired
Permit Number: T06CM00851
Permit Description: NEW SFR
Total Completed Inspections - 26
Date Description Inspector Results Comments
08/18/2006 NPPO PRE PERMIT INSPECTION ACONNOR Approved
10/29/2006 EXCAVATION/LAYOUT REBAR & ZON WNORTH Approved IVRS - Inspection :*
1) WITHIN SURVEYORS STAKES
10/29/2006 ELECTRIC - UFER WNORTH Approved IVRS - Inspection :*
11/08/2006 STEM WALL/RETAINING WALL WNORTH Approved IVRS - Inspection :*
11/17/2006 PLUMBING - ROUGH, SOIL WNORTH Approved IVRS - Inspection :*
1) NOTE: LOCATION OF 3" UP AT POWDER ROOM/GARAGE HAS BEEN CHANGED FROM PLAN
2) ADDITIONAL 2" NEAR POWDER TOILET ROOM HAS BEEN ADDED
3) PROCEED IF THIS WAS NOT DONE IN ERROR
12/12/2006 PLUMBING - PRE SLAB WNORTH Approved IVRS - Inspection :*
12/12/2006 ELECTRIC - UNDERGROUND WNORTH Approved IVRS - Inspection :*
12/13/2006 BUILDING PRE-SLAB WNORTH Approved IVRS - Inspection :*
03/06/2007 ROOF NAILING WNORTH Approved IVRS - Inspection :*
03/06/2007 EXT METAL CLIPS/EXT SHEATHING WNORTH Approved IVRS - Inspection :*
05/10/2007 PLUMBING - GAS PRESSURE TEST WNORTH Approved IVRS - Inspection :*
05/10/2007 PLUMBING - YARD WTR LINE/TEST WNORTH Approved IVRS - Inspection :*
05/10/2007 ELECTRIC - TEMPORARY SERVICE WNORTH Approved IVRS - Inspection :*
05/10/2007 ELECTRIC - CABLE DROP WNORTH Approved IVRS - Inspection :*
05/10/2007 U VALUE FOR WINDOW WNORTH Approved IVRS - Inspection :*
05/10/2007 STUCCO MESH WNORTH Approved IVRS - Inspection :*
05/11/2007 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER W. NORTH
05/18/2007 PLUMBING - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
05/18/2007 ELECTRIC - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
05/24/2007 MECHANICAL - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
05/24/2007 FRAMING WNORTH Approved IVRS - Inspection :*
07/06/2007 SHEET ROCK NAILING WNORTH Approved IVRS - Inspection :*
1) NAIL OFF OVER WINDOW N.E. BEDROOM
11/09/2007 PLUMBING - SEWER HCS CONNECT WNORTH Approved IVRS - Inspection :*
1) CONNECTED TO SEPTIC SYSTEM PERMIT #P06CP06120 APP BY PIMA COUNTY 11/07/07
12/28/2007 ELECTRIC - FINAL WNORTH Approved IVRS - Inspection :
See detailed listing on site.| 999*
01/02/2008 SEPTIC - SYSTEM WNORTH Approved IVRS - Inspection :*
01/02/2008 PLUMBING - GAS PRESS TEST FNL WNORTH Approved IVRS - Inspection :*

Documents