Permit: T06CM00558
Permit Details
Status:
Si_xpire
Type:
SINGLE FAMILY NEW
Address:
7607 E CHOLLA OVERLOOK DR
Address NEW:
7607 E CHOLLA OVERLOOK DR
Apply Date:
01/25/2006
Applicant:
N/A
Description:
SFR:TD16-32-48
Contractors:
- K B HOME OF TUCSON *C
Permit Reviews
Permit Number - T06CM00558
Permit Status: Si_xpire
Permit Description: SFR:TD16-32-48
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/25/2006 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 02/02/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM00558
Permit Status: Si_xpire
Permit Description: SFR:TD16-32-48
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 01/25/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 01/25/2006 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Si_xpire
Permit Number: T06CM00558
Permit Description: SFR:TD16-32-48
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/02/2006 | PLUMBING - YARD WTR LINE/TEST | FSALDIVA | Approved | IVRS - Inspection : See detailed listing on site.| 999* NO WATER METER |
| 06/02/2006 | PLUMBING - SEWER HCS CONNECT | FSALDIVA | Approved | IVRS - Inspection :* |
| 06/02/2006 | PLUMBING - YARD WTR LINE/TEST | FSALDIVA | Approved | IVRS - Inspection :* |
| 06/02/2006 | PLUMBING - ROUGH, SOIL | FSALDIVA | Approved | IVRS - Inspection :* |
| 06/16/2006 | BUILDING PRE-SLAB | DQUINN | Approved | IVRS - Inspection :* |
| 06/16/2006 | EXCAVATION/LAYOUT REBAR & ZON | DQUINN | Approved | IVRS - Inspection :* |
| 07/25/2006 | ROOF NAILING | DQUINN | Approved | IVRS - Inspection :* |
| 07/28/2006 | EXT METAL CLIPS/EXT SHEATHING | DQUINN | Approved | IVRS - Inspection :* |
| 08/25/2006 | ELECTRIC - TEMPORARY SERVICE | DQUINN | Approved | |
| 08/25/2006 | ELECTRIC - CABLE DROP | DQUINN | Approved | IVRS - Inspection :* |
| 08/28/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER D. QUINN |
| 10/17/2006 | STUCCO MESH | DQUINN | Approved | FINISH AT EAST WINDOW |
| 10/18/2006 | PLUMBING - GAS PRESSURE TEST | DQUINN | Approved | IVRS - Inspection :* |
| 10/18/2006 | MECHANICAL - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 10/18/2006 | PLUMBING - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 10/18/2006 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 10/18/2006 | ELECTRIC - UFER | DQUINN | Approved | IVRS - Inspection :* |
| 10/18/2006 | U VALUE FOR WINDOW | DQUINN | Approved | IVRS - Inspection :* |
| 10/23/2006 | FRAMING | DQUINN | Approved | IVRS - Inspection :* |
| 11/07/2006 | SHEET ROCK NAILING | DQUINN | Approved | |
| 01/09/2007 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection :* 1) NEED P.T. CERT |
| 01/09/2007 | MECHANICAL - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 01/09/2007 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 01/09/2007 | ELECTRIC - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 01/09/2007 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 01/09/2007 | PLUMBING - GAS PRESS TEST FNL | DQUINN | Approved | IVRS - Inspection :* |
| 01/09/2007 | ELECTRIC - CONSTRUCTION POWER | DQUINN | Approved | IVRS - Inspection :* |