Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T06CM00520
Permit Details
Apply Date:
01/24/2006
Applicant:
CLINE AMANDA & MICHAEL
Description:
ADDITION:LAUNDRY & REBUILD PORCH AT REAR R1 Delete porch R2 Revise ledger and ceiling nailer at addition
Architects:
- WATSON, JAMES RICHARD
Permit Reviews
Permit Number - T06CM00520
Permit Status: Final
Permit Description: ADDITION:LAUNDRY & REBUILD PORCH AT REAR
R1 Delete porch
R2 Revise ledger and ceiling nailer at addition
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/24/2006 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 01/24/2006 | COMPLETED |
06/16/2006 | REVISION - - 1ST | 06/23/2006 | COMPLETED |
06/27/2006 | REVISION - - 2ND | 06/27/2006 | COMPLETED |
07/07/2006 | REVISION - - 3RD | 07/07/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM00520
Permit Status: Final
Permit Description: ADDITION:LAUNDRY & REBUILD PORCH AT REAR
R1 Delete porch
R2 Revise ledger and ceiling nailer at addition
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
01/24/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06CM00520
Permit Description: ADDITION:LAUNDRY & REBUILD PORCH AT REAR
R1 Delete porch
R2 Revise ledger and ceiling nailer at addition
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/05/2006 | BUILDING PRE-SLAB | RCAMACHO | Approved | IVRS - Inspection :* |
06/27/2006 | PLUMBING - SEWER HCS CONNECT | FSALDIVA | Approved | IVRS - Inspection :* |
06/27/2006 | PLUMBING - SEWER HCS CONNECT | FSALDIVA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
06/27/2006 | ELECTRIC - CABLE DROP | FSALDIVA | Approved | IVRS - Inspection :* |
06/28/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | RECN CLEARED PER F. SALDIVAR |
06/29/2006 | ROOF NAILING | WNORTH | Approved | IVRS - Inspection :* |
07/07/2006 | ELECTRIC - UFER | RCAMACHO | Approved | |
07/07/2006 | EXCAVATION/LAYOUT REBAR & ZON | RCAMACHO | Approved | IVRS - Inspection :* |
07/11/2006 | EXT METAL CLIPS/EXT SHEATHING | RCAMACHO | Approved | IVRS - Inspection :* |
07/11/2006 | PLUMBING - GAS PRESSURE TEST | RCAMACHO | Approved | IVRS - Inspection :* |
07/11/2006 | STUCCO MESH | RCAMACHO | Approved | IVRS - Inspection :* |
07/14/2006 | SHEET ROCK NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
09/27/2006 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
09/27/2006 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
09/27/2006 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
09/27/2006 | FRAMING | RCAMACHO | Approved | IVRS - Inspection :* |
09/27/2006 | PLUMBING - ROUGH, SOIL | RCAMACHO | Approved | IVRS - Inspection :* |
09/28/2006 | ELECTRIC - SERVICE RELOCATION | RCAMACHO | Approved | |
09/28/2006 | MECHANICAL - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
09/28/2006 | PLUMBING - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
09/28/2006 | ELECTRIC - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
09/28/2006 | BUILDING - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
10/10/2006 | PERMIT FINALED | JWEATHER | Approved |