Permit: T06CM00074
Permit Details
Apply Date:
01/05/2006
Applicant:
OUTPOST DEVELOPMENT
Description:
SFR: TD# 16-36-90
Contractors:
- OUTPOST DEVELOPMENT
Permit Reviews
Permit Number - T06CM00074
Permit Status: C of o
Permit Description: SFR: TD# 16-36-90
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/05/2006 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 01/11/2006 | COMPLETED |
| 02/07/2007 | REVISION - - 1ST | 02/07/2007 | COMPLETED |
| 03/22/2006 | 3RD PARTY REVIEW-REVISION/OTHER | 03/22/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM00074
Permit Status: C of o
Permit Description: SFR: TD# 16-36-90
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/05/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM00074
Permit Description: SFR: TD# 16-36-90
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/16/2006 | PLUMBING - ROUGH, SOIL | WNORTH | Approved | IVRS - Inspection :* 1) NOTE: A 3" CLEANOUT WILL BE REQUIRED AT THE HALL BATHROOM |
| 04/06/2006 | EXCAVATION/LAYOUT REBAR & ZON | WNORTH | Approved | 1) PORCH NOT READY 2) ONLY ABLE TO LOCATE ONE SURVEYORS PIN FOR LOCATION. CONFIRM LOCATION PRIOR TO POUR 3) POUR AT OWN RISK |
| 04/06/2006 | ELECTRIC - UFER | WNORTH | Approved | |
| 04/06/2006 | BUILDING PRE-SLAB | WNORTH | Approved | |
| 06/07/2006 | ROOF NAILING | WNORTH | Approved | IVRS - Inspection :* 1) NEED REVISED PLOT PLAN SHOWING PORCH |
| 06/14/2006 | MECHANICAL - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 06/14/2006 | U VALUE FOR WINDOW | WNORTH | Approved | IVRS - Inspection :* |
| 06/14/2006 | STUCCO MESH | WNORTH | Approved | IVRS - Inspection :* |
| 06/15/2006 | PLUMBING - GAS PRESSURE TEST | WNORTH | Approved | IVRS - Inspection :* |
| 06/15/2006 | PLUMBING - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 06/15/2006 | ELECTRIC - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
| 06/15/2006 | FRAMING | WNORTH | Approved | IVRS - Inspection :* |
| 06/15/2006 | EXT METAL CLIPS/EXT SHEATHING | WNORTH | Approved | IVRS - Inspection :* |
| 06/23/2006 | SHEET ROCK NAILING | WNORTH | Approved | IVRS - Inspection :* 1) NOTE: THE WAY THESE HOUSES WERE PLUMBED WE NEED A 3" CLEANOUT IN THE HALL BATH PRIOR TO FINALS. SEE SOIL NOTES. RECOMMEND INSTALLING PRIOR TO S/R FINISH |
| 08/18/2006 | ELECTRIC - TEMPORARY SERVICE | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 08/18/2006 | ELECTRIC - CABLE DROP | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 08/21/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER W. NORTH |
| 11/13/2006 | PLUMBING - SEWER HCS CONNECT | WNORTH | Approved | IVRS - Inspection :* 1) INSPECTION CARD NOT ON SITE |
| 11/13/2006 | PLUMBING - YARD WTR LINE/TEST | WNORTH | Approved | IVRS - Inspection :* |
| 12/27/2006 | BUILDING - FINAL | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) REPAIR STUCCO A/C DRAIN 2) WIRE IN IRRIGATION 3) WIRE TO POST LIGHTS NOT INSPECTED 4) SECURE BACK PORCH RECEPTACLE 5) NO GARAGE/OUTSIDE GFI 6) IRRIGATION LINE OVER SIDE WALK 7) NO FUSE GARAGE SRU 8) NEED ROOF ACCESS FOR A/C 9) OPEN GROUND BEDROOM #3 10) RECEPTACLE NEXT TO PANTRY INOPERABLE 11) NEED SWITCHED LIGHT SOURCE EVERY ROOM 12) FRONT PORCH AND WINDOW EYE BROW NOT ON PLOT PLAN 13) NEED WEEP BLOCK BY FRONT GATE 14) ROADS |
| 12/27/2006 | MECHANICAL - FINAL | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/27/2006 | PLUMBING - FINAL | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/27/2006 | ELECTRIC - FINAL | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 01/05/2007 | PLUMBING - GAS PRESS TEST FNL | WNORTH | Approved | IVRS - Inspection :* |
| 02/21/2007 | PERMIT FINALED | JWEATHER | Approved |