Permit: T06BU01613
Permit Details
Apply Date:
06/21/2006
Applicant:
CASAS BONITAS CUSTOM HOMES LLC
Description:
RETAINING WALL: 5' HIGH 30 LF
Contractors:
- CASAS BONITAS CUSTOM HOMES LLC
Permit Reviews
Permit Number - T06BU01613
Permit Status: Si_xpire
Permit Description: RETAINING WALL: 5' HIGH 30 LF
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/21/2006 | WALLS SUBMITTAL | 06/23/2006 | COMPLETED |
| 06/23/2006 | WALLS SUBMITTAL | 08/31/2006 | COMPLETED |
| 08/31/2006 | RESUBMITTAL | 09/01/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06BU01613
Permit Status: Si_xpire
Permit Description: RETAINING WALL: 5' HIGH 30 LF
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 06/21/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 07/20/2006 | · Contractor is to provide positive drainage away from structure as shown on the approved grading plan for Sentinel Shadows. · Retaining wall is to be constructed entirely on the higher lot (Lot 36). Owner of Lot 36 is to maintain retaining wall and to provide positive drainage away from structure and wall with out causing hydrostatic pressure on the wall that would adversely affect adjacent lots. |
Outstanding Inspections
Permit Status: Si_xpire
Permit Number: T06BU01613
Permite Description: RETAINING WALL: 5' HIGH 30 LF
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| PERMIT FINALED | N/A | Not Inspected |
Completed Inspections
Permit Status: Si_xpire
Permit Number: T06BU01613
Permit Description: RETAINING WALL: 5' HIGH 30 LF
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2006 | EXCAVATION/LAYOUT REBAR & ZON | AALEGRIA | Approved | IVRS - Inspection :* NOTE: 4'-0" C.M.U RETAINING WALL ON EAST SIDE OF LOT DETAILS OF REINFORCED V - BARS #4 @ 32" O.C Y - DOWEL BARS #4 @ 32" O.C X - BARS #4 @ 32" O.C FOR STEM WALL/RETAINING WALL INSPECTION MUST PROVIDE CMU, VERTICAL REINF. X-BARS #4 @ 32" O.C 2 #4 CONT. ON BOND BEAM. MIN. OVER GAP. 24" ON REBAR #4 |
| 09/26/2006 | BUILDING - FINAL | AALEGRIA | Approved | IVRS - Inspection :* |
| 09/26/2006 | STEM WALL/RETAINING WALL | AALEGRIA | Approved | IVRS - Inspection :* |
| 09/26/2006 | REINFORCED MASONRY PRE-GROUT | AALEGRIA | Approved | IVRS - Inspection :* |