Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Si_xpire
Type:
COMMERCIAL WAL
Address:
1442 W KANDY CT
Address NEW:
1442 W KANDY CT
Apply Date:
06/21/2006
Applicant:
CASAS BONITAS CUSTOM HOMES LLC
Description:
RETAINING WALL: 5' HIGH 30 LF
Contractors:
  • CASAS BONITAS CUSTOM HOMES LLC

Permit Reviews

Permit Number - T06BU01613
Permit Status: Si_xpire
Permit Description: RETAINING WALL: 5' HIGH 30 LF
Start Date Submittal Complete Date Status  
06/21/2006 WALLS SUBMITTAL 06/23/2006 COMPLETED Review Details
06/23/2006 WALLS SUBMITTAL 08/31/2006 COMPLETED Review Details
08/31/2006 RESUBMITTAL 09/01/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06BU01613
Permit Status: Si_xpire
Permit Description: RETAINING WALL: 5' HIGH 30 LF
Total Outstanding Activity Conditions - 2
Date Name
06/21/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
07/20/2006 · Contractor is to provide positive drainage away from structure as shown on the approved grading plan for Sentinel Shadows. · Retaining wall is to be constructed entirely on the higher lot (Lot 36). Owner of Lot 36 is to maintain retaining wall and to provide positive drainage away from structure and wall with out causing hydrostatic pressure on the wall that would adversely affect adjacent lots.

Outstanding Inspections

Permit Status: Si_xpire
Permit Number: T06BU01613
Permite Description: RETAINING WALL: 5' HIGH 30 LF
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
PERMIT FINALED N/A Not Inspected

Completed Inspections

Permit Status: Si_xpire
Permit Number: T06BU01613
Permit Description: RETAINING WALL: 5' HIGH 30 LF
Total Completed Inspections - 4
Date Description Inspector Results Comments
09/20/2006 EXCAVATION/LAYOUT REBAR & ZON AALEGRIA Approved IVRS - Inspection :*
NOTE: 4'-0" C.M.U RETAINING WALL ON EAST SIDE OF LOT
DETAILS OF REINFORCED V - BARS #4 @ 32" O.C
Y - DOWEL BARS #4 @ 32" O.C
X - BARS #4 @ 32" O.C

FOR STEM WALL/RETAINING WALL INSPECTION
MUST PROVIDE CMU, VERTICAL REINF. X-BARS #4 @ 32" O.C
2 #4 CONT. ON BOND BEAM. MIN. OVER GAP. 24" ON REBAR #4
09/26/2006 BUILDING - FINAL AALEGRIA Approved IVRS - Inspection :*
09/26/2006 STEM WALL/RETAINING WALL AALEGRIA Approved IVRS - Inspection :*
09/26/2006 REINFORCED MASONRY PRE-GROUT AALEGRIA Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW