Permit: T05PL01709
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
9841 E MARIANNE ST
Address NEW:
9841 E MARIANNE ST
Apply Date:
10/24/2005
Applicant:
ARIZONA PLUMBING SERVICES, DBA SEARS,*C
Description:
REPLACE: WATER HEATER
Contractors:
- ARIZONA PLUMBING SERVICES, DBA SEARS,*C
Outstanding Activity Conditions
Permit Number - T05PL01709
Permit Status: Expired
Permit Description: REPLACE: WATER HEATER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/24/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05PL01709
Permite Description: REPLACE: WATER HEATER
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2005 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. REMOVE TAPE AT SINGLE TO DOUBLE WALL VENT CONNECTION 2. PROVIDE 3-GALV SCREWS AT EACH JOINT OF WATER HEATER VENT PIPING. 3. PROVIDE PROOF OF T & P GRAVITY DRAIN TO DAYLIGHT. 4. VENT FROM WATER HEATER SHALL BE 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE WITH APPROVED VENT PIPING & CAP |