Permit: T05PL00909
Permit Details
Apply Date:
05/18/2005
Applicant:
CALS PLUMBING L L C,*C
Description:
GAS LINE (APA)
Contractors:
- CALS PLUMBING L L C,*C
Outstanding Activity Conditions
Permit Number - T05PL00909
Permit Status: Expired
Permit Description: GAS LINE (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/18/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05PL00909
Permite Description: GAS LINE (APA)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/19/2005 | PLUMBING - GAS PRESSURE TEST | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 05/19/2005 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RISER AT HOUSE MUST BE PRIMERED AND TAPED OR USE SCOTCH COATED PIPE & FITTING MUST BE RE-TAPED. 2) PROVIDE A MIN. 10LB TEST ON ENTRIRE GAS SYSTEM. 3) PROVIDE AN APPROVED SHUT OFF VALVE AT FURNACE. 4) PROVIDE MIN 3 SCREWS IN EACH JOINT OF WATER HEATER VENT CONNECTOR. 5) PROVIDE HIGH & LOW COMBUSTION AIR OPENINGS INTO WATER HEATER ROOM. |