Description:
GAS LINE (APA)
Contractors:
  • CALS PLUMBING L L C,*C

Outstanding Activity Conditions

Permit Number - T05PL00909
Permit Status: Expired
Permit Description: GAS LINE (APA)
Total Outstanding Activity Conditions - 1
Date Name
05/18/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T05PL00909
Permite Description: GAS LINE (APA)
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
05/19/2005 PLUMBING - GAS PRESSURE TEST N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/19/2005 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) RISER AT HOUSE MUST BE PRIMERED AND TAPED OR USE SCOTCH COATED PIPE & FITTING MUST BE RE-TAPED. 2) PROVIDE A MIN. 10LB TEST ON ENTRIRE GAS SYSTEM. 3) PROVIDE AN APPROVED SHUT OFF VALVE AT FURNACE. 4) PROVIDE MIN 3 SCREWS IN EACH JOINT OF WATER HEATER VENT CONNECTOR. 5) PROVIDE HIGH & LOW COMBUSTION AIR OPENINGS INTO WATER HEATER ROOM.