Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
6558 E CALLE CAVALIER
Apply Date:
03/14/2005
Applicant:
MEISNER VICKI
Description:
Install WH 40 Gal Gas
Contractors:
  • PLUMB PLUMBING L L C

Outstanding Activity Conditions

Permit Number - T05PL00500
Permit Status: Expired
Permit Description: Install WH 40 Gal Gas
Total Outstanding Activity Conditions - 1
Date Name
03/14/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T05PL00500
Permite Description: Install WH 40 Gal Gas
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
03/22/2005 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999* PROVIDE A LOW COMBUSTION AIR VENT WITHIN 12" OF BOTTOM OF ENCLOSURE. PROVIDE MIN. 3 SCREWS IN JOINTS OF VENT CONNECTOR. ALTERNATE METHOD OF RUNNING T & P DRAIN NOT APPLICABLE IN THIS CASE. RUN T & P DRAIN THROUGH AN EXTERIOR WALL TO DAYLIGHT. PAT 290-8809