Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Apply Date:
03/07/2005
Applicant:
ALFONSE PACHECO
Description:
REPAIR:GAS LINE

Permit Reviews

Permit Number - T05PL00450
Permit Status: Closed
Permit Description: REPAIR:GAS LINE
Start Date Submittal Complete Date Status  
03/07/2005 PLUMBING 03/07/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05PL00450
Permit Status: Closed
Permit Description: REPAIR:GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
03/07/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Closed
Permit Number: T05PL00450
Permit Description: REPAIR:GAS LINE
Total Completed Inspections - 2
Date Description Inspector Results Comments
03/10/2005 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :* 1) WATER HEATER VENT TO BE 3' ABOVE TOP OF COOLER WHEN WITHIN 10' OF COOLER INTAKES. 2) WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPING TO BE FULL SIZE RIDGID PIPING GRAVITY DRAIN TO DAYLIGHT. 3) SUPPORT ROOF TOP PIPING CORRECTLY. 10 PSI AIR TEST FROM METER ( REPAIR) TO STOVE, WATER HEATER & ROOF TOP UNIT OK
03/10/2005 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW