Permit: T05PL00282
Permit Details
Apply Date:
02/14/2005
Applicant:
RUMLER REPAIRS , JACK
Description:
REPAIR:GAS LINE DUPLEX
Contractors:
- RUMLER REPAIRS , JACK
Permit Reviews
Permit Number - T05PL00282
Permit Status: Closed
Permit Description: REPAIR:GAS LINE DUPLEX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/14/2005 | PLUMBING | 02/14/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05PL00282
Permit Status: Closed
Permit Description: REPAIR:GAS LINE DUPLEX
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/14/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T05PL00282
Permite Description: REPAIR:GAS LINE DUPLEX
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/21/2005 | PLUMBING - FINAL | N/A | Partial Approval | IVRS - Inspection :* |
Completed Inspections
Permit Status: Closed
Permit Number: T05PL00282
Permit Description: REPAIR:GAS LINE DUPLEX
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/18/2005 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK. 2) NOTE: SHALL PROVIDE 2- 10" X 10" LOUVER GRILLS LOCATED 12" BELOW CEILING AND 12" ABOVE FLOOR FOR WATER HTR ENCLOSURE THEN CALL FOR FINAL INSPECTION. 3) PROVIDE GALVANIZED T & P DRAIN. BLK PIPE NOT APPROVED MATERIAL. AFTER HRES INSPECTION FEE PAID IN FULL. SAME FOR 2622 E EASTLAND |