Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Apply Date:
07/15/2005
Applicant:
JEFFREY A STANLEY
Description:
FLOODPLAIN USE PERMIT

Permit Reviews

Permit Number - T05OT01755
Permit Status: Final
Permit Description: FLOODPLAIN USE PERMIT
Start Date Submittal Complete Date Status  
07/15/2005 FLOODPLAIN 08/10/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05OT01755
Permit Status: Final
Permit Description: FLOODPLAIN USE PERMIT
Total Outstanding Activity Conditions - 1
Date Name
07/22/2005 FLOOD USE PERMIT CONDITIONS JULY 22, 2005 FLOODPLAIN USE PERMIT NO. T05OT01755 ADDRESS: 2075 W. GARDNER LANE Suites 101-106 (IN) Suites 107-113 (OUT) PROPERTY OWNER: WINDMILL DEVELOPMENT The applicant is authorized to use a portion of the City of Tucson the property described as (legal description): 104-06-011E 1. This permit is for the purpose of a 20,100 sq. ft. Non-Residential structure to be constructed within a FEMA floodplain. FIRM Panel1617K, Zone A0+1, Dated February 08, 1999 2. The proposed building is impacted by the regulatory floodplain. The floodplain 100-year water surface elevation (WSE) just upstream of the proposed building is 2277.00 feet. The building must be elevated above the floodplain 100-year WSE. This can be achieved by either building up the building pad to the 100-year WSE or higher, or elevating the building by any other acceptable method such as stem walls, piers, etc, depending on what the drainage report, the engineer or the owner is proposing. The building lowest finish floor, utilities, machinery, equipment (i.e. furnaces, water heaters, heat pumps, air conditioners and their associated equipment, including all electrical equipment), or an open utility platform that provides utility services for the structure on this property, under this permit shall, be placed at a minimum of 2 feet above the existing ground, NAVD 1988 as certified by a Registered Land Surveyor. 3. Finish Floor Elevation for Suites 101-106. Ste. 101, FFE:2276.5 Ste. 102 & 103, FFE: 2277.08 Ste. 104 & 105, FFE: 2277.67 Ste. 106, FFE: 2278.25 NOTICE This Certification (Elevation Certificate) is required and must be completed and returned to Development Services Department, Engineering Division, on the first floor of the County/City Public Works Building at 201 N. Stone Avenue. This Certification must be completed and returned prior to the final inspection, occupancy of the structure, or issuance of Certificate of Occupancy. Xref: T05CM01364 & T05BU00686

Documents

File Name Document Type  
FINAL T05OT01755 STE 104 1-29-07.PDF ELEVATION CERT VIEW
FINAL T05OT01755 STE 102 1-29-07.PDF ELEVATION CERT VIEW
FINAL T05OT01755 STE 103 1-29-07.PDF ELEVATION CERT VIEW
FINAL T05OT01755 STE 101 1-29-07.PDF ELEVATION CERT VIEW
FINAL T05OT01755 STE 105 1-29-07.PDF ELEVATION CERT VIEW
FINAL T05OT01755 STE 106 1-29-07.PDF ELEVATION CERT VIEW